4.2.3. ETH
Standard RJ45 connector for ethernet connection. RipEX has 10/100 BaseT Auto MDI/MDIX interface
so it can connect to 10 Mbps or 100 Mbps ethernet network. The speed can be selected manually or
recognised automatically by RipEX. RipEX is provided with Auto MDI/MDIX function which allows it to
connect over both standard and cross cables, adapting itself automatically.
Pin assignement
Fig. 4.8: RJ-45F
Tab. 4.2: Ethernet to cable connector connections
Crossed cable
Direct cable
Signal
PIN
green – white
orange – white
TX+
1
green
orange
TX−
2
orange – white
green – white
RX+
3
blue
blue
—
4
blue – white
blue – white
—
5
orange
green
Rx−
6
brown – white
brown – white
—
7
brown
brown
—
8
4.2.4. COM1 and COM2
RipEX provides two serial interfaces COM1 and COM2 terminated by DSUB9F connectors. COM1 is
always RS232, COM2 can be configured as RS232 or RS485 (more in
Adv. Conf., COM's
).
RipEX‘s RS232 is a hard-wired DCE (Data Communication Equipment) device. Equipment connected
to the RipEX’s serial ports should be DTE (Data Terminal Equipment) and a straight-through cable
should be used. If a DCE device is connected to the RipEX‘s serial ports, a null modem adapter or
cross cable has to be used.
Fig. 4.9: Serial connector
Tab. 4.3: COM1,2 pin description
COM2 – RS485
COM1, 2 – RS232
DSUB9F
In/ Out
signal
In/ Out
signal
pin
—
O
CD
1
I/O
line B
O
RxD
2
I/O
line A
I
TxD
3
—
I
DTR
4
GND
GND
5
—
O
DSR
6
—
I
RTS
7
—
O
CTS
8
—
—
—
9
RipEX keeps pin 6 DSR at the level of 1 by RS232 standard permanently.
41
© RACOM s.r.o. – RipEX Radio modem & Router
Product