Ultra Dash Installation
3
Ultra Dash Installation
Selecting a Mounting Location
Select a mounting location that does not expose the Ultra Dash to high temperatures. Avoid exposing the
front LCD to direct sunlight. Extreme overheating from the sun can temporarily cause the LCD to turn
entirely black. Although the dash is water resistant (i.e. rain, snow), you should never submerge any part of
the dash under water.
Dash Mounting
Once you have decided on a mounting location use the supplied template to cut out the rear dash inserts and
drill holes for the mounting studs.
Use the supplied machine nuts and locking washers to bolts in the dash. Do not use thread lock or nylock
nuts on the mounting studs.
Port Descriptions
Connector Locations
Port B
Serial Port
V-Net Port Port A
Port A ---
Port A is used to connect the main power source, warning indicator inputs, Ace setting input,
engine RPM and jack shaft rpm inputs. See the section
Port A Wiring
for complete instructions.
Port B ---
Port B is used to connect the 4 EGT probes, water temperature sensor, external warning output
and external battery. The EGT probes are sold separately and are not factory installed in the connector.
You must install the probes in to the appropriate connector position yourself. See the section
Port B
Wiring
for complete instructions.
Serial Port ---
The serial port is used to program the dash and download data using the DataLink PC
software.
V-Net Port ---
The V-Net can be used to install up to 5 additional analog or digital inputs.
Summary of Contents for Ultra Dash Xtreme
Page 1: ...Racepak Ultra Dash Installation and Operation Instructions 300 DS UDX6S...
Page 2: ......
Page 6: ...Introduction 2...
Page 14: ......
Page 26: ......
Page 36: ......