SDC2000
16 / 40
User Manual
Rev. 1.0 - 12/04/05
a reception phase error condition. When enabled
"[Phas]", in the event of an error the system switches to
analogue (if allowed). When disabled "[--]", in the event
of an error the system will not switch to analogue (if
allowed). When an alarm is triggered by a SUB-FRAME
phase error, it is reported in field Sts (Sts:[02]).
•
[Pari] This field enables or disables detection of a
reception parity error condition. When enabled "[Pari]",
in the event of an error the system switches to analogue
(if allowed). When disabled "[--]", in the event of an error
the system will not switch to analogue (if allowed). When
an alarm is triggered by a received frame parity error, it
is reported in field Sts (Sts:[01]).
•
[PLL] This field reports a "PLL not locked to received
signal" condition. This error only occurs when there is
no physical connection between source and
equipment; the PLL locks to the digital signal carrier,
regardless of information content. When an alarm is t
triggered by a PLL not locked condition, it is reported in
field Sts (Sts:[10]).
NOTE:
When more than one error occurs, this is reported
in binary format among those enabled (binary system: 0, 1,
2, 3, 4, 5, 6, 7, 8, 9, A, B, C, D, E, F).
[AUTO]
Push the encoder when this item is blinking to select
the input used by the system. Move the knob back or
forward in edit mode to choose ANALOGue, DIGITal or
AUTOmatic input. In AUTOmatic, the system switches
to digital when a valid (although mute) connection is
present.
[SCAoff]
Push the encoder when this item is blinking to change
the input switch. You can toggle between SCAoff and
SCAon.
[Input] (version with DIGITAL MPX)
If the encoder is pushed when in this submenu, field [BACK] begins
to blink and you will be able to move the cursor from field to field by
turning the knob in the desired direction.
Push the encoder again when a field is selected to confirm that you
wish to edit the current selection.