SDC2000
22 / 40
User Manual
Rev. 1.0 - 12/04/05
[BACK]
Push the encoder when this item is blinking to cancel
selection mode and go back to scrolling through display
screens by turning the knob.
[STEREO]Push the encoder when this item is blinking to select
MPX signal type; available options are STEREO, MONO
L and EXTERN (external).
•
STEREO: outputs the stereophonic signal with the 19
kHz pilot tone.
•
MONO L: outputs the processed left input signal.
•
EXTERN: outputs the signal present at the MPX-IN
input.
[P.00uS]
Push the encoder when this item is blinking to select
preemphasis type; available options are 0, 50 and 75
uSec.
[+L/+R]
Push the encoder when this item is blinking to select R
(right channel) input phase. Push the knob bR
and - R, i.e. out of phase right channel in phase opposition.
[pilote]
In this submenu, you may use the knob to set analogue
output levels.
•
[BACK] Push the encoder when this item is blinking
to cancel selection mode and go back to scrolling
through display screens by turning the knob.
•
[IS ON] This field lets you select pilot frequency state.
It can be toggled between IS ON (Pilot ON) and IS OFF
(Pilot OFF).
•
level:[-20,00] This field lets you set the level of the 19
kHz pilot tone present at the MPX output. Setting range
is -32.8 dB to -7.3 dB in 0.1 dB increments.
NOTE: The 19 kHz frequency at MONITOR output is
unaffected by this parameter.
•
Phase:[+00,00] This field lets you set the pilot tone
phase with respect to the 38 kHz suppressed carrier.
Setting range is +/-15.16° in 0.12° increments.
NOTE: The 19 kHz frequency at MONITOR output will
always be in phase with the 19 kHz frequency on MPX.