3
rd
Generation Compact RDMS
TM
Telemetry Receiver
56
Quasonix, Inc.
1 - Enabled
MI [TS {M <i>|T <i>|H <i>}]
M <i> - Sets modulation index trellis maximum index to <i>, 0.000 to 8.000
T <i> - Sets modulation index trellis target index to <i>, 0.000 to 8.000
H <i> - Sets modulation index trellis hysteresis to <i>, 0.000 to 8.000
Examples:
MI
Modulation index scaling mode acquire (Triggered at 27.57 Eb/N0)
Modulation index 0.701, estimated index 0.701
Tracking mode hold threshold 10.000 Eb/N0
Tracking mode hold enabled
Acquire mode delta H 0.005
Acquire mode settle time 500 ms
Operation persistence disabled
MI x
Sets mod index scale to a value between 0.350 and 8.000 and forces mode to hold at
specified value
MI O
Disable Mod Index Tracking (Set to h=0.7)
MI A
Acquire mode enable
MI A D
Sets the maximum delta h (indicates a change in h defaults to 0.005)
MI A S
Sets the delta h settling time defaults to 500 ms
MI H
Hold Mod Index Tracking at current position
MI I
Sets Trellis Index
MI T
Tracking mode enable
MI T H x
Sets the Tracking Hold threshold below Eb/N0 (x)
Valid range is -20.000 to 30.000
4.3.2.27 Modulation - MO
The MO command displays and controls mode settings.
MO [<m>]
- Sets the demodulation mode to <m>
where: <m> - Mode
{0|PCMFM} - Pulse Code Modulation/Frequency Modulation
{1|SOQPSK} - Shaped Offset Quadrature Phase Shift Keying
{2|MhCPM} - Multi-h Continuous Phase Modulation
{3|BPSK} - Bi-Phase Phase Shift Keying
{4|QPSK} - Quadrature Phase Shift Keying