3
rd
Generation Compact RDMS
TM
Telemetry Receiver
61
Quasonix, Inc.
PL 1
Set the current power level information tracking display to On
PL C A
- Sets power level automatic control mode
Examples:
PL C A 0
Set the power level automatic control mode to Software
PL C A 1
Set the power level automatic control mode to Hardware
PL F
- Sets the average and adjusted power level filter coefficient
Example:
PL F 5
Set the power level filter coefficient to 5
Valid range is 1 to 16
PL M
- Sets the power level measurement type
Examples:
PL M 0
Set the power level measurement type to Total Power
PL M 1
Set the power level measurement type to Signal Power
PL S
- Sets the power level scale value
Example:
PL S 2.517
Set the power level scale value to 2.517
Valid range is 0.000 to 7.996
4.3.2.32 Phase Noise Compensation - PNC
The PNC command reports or sets the phase noise compensation state.
Examples:
PNC
Phase noise compensation off
PNC 0 Set phase noise compensation to Off
PNC 1 Set phase noise compensation to On
4.3.2.33 Query Temperature - QT
The Query Temperature command reports the temperature in degrees Celsius.
Example:
QT
FPGA temperature: 41.0
°
C (85
°
C Max)
Demod temperature: 43.0
°
C (85
°
C Max)
4.3.2.34 Signal Degradation Information - SDI
The Signal Degradation Information command sets and displays a variety of signal degradation information settings.