3
rd
Generation Compact RDMS
TM
Telemetry Receiver
81
Quasonix, Inc.
Mnemonic
Name
Description
BER D
Bit Error Rate
Output
Display
Set the bit error output display to a specific style and display rate
BER [D {<s> [<r>]|R|?}]
<s> [<r>] - Sets bit error output display style to <s> at rate <r>
where:
<s> - Style
O - Off
N - Normal
W - Wide
C - CSV (Comma Separated Values)
<r> - Display rate <r>, 100 to 60000 ms
R - Reset Display
? - Display style help
Examples:
BER D ?
Display bit error rate style help
BER D 0
Set bit error rate style to Off
BER D N
Set it error rate style to Normal
BER D W
Set bit error rate style to Wide
BER D W 42
Set bit error rate style to Wide with a display rate of 42
Valid range for display rate is 100 to 60000 ms
BER D CSV
Set bit error rate style to Comma Separated Values
BER D R
Reset display
BER G n
Set Bit Error
Measurement
Gating
Sets bit error measurement gating
The test can be configured to make a single measurement or, when a
time limit, bit count, or error count is set, automatically repeat the test.
BER [G <n>]
Sets bit error measurement gating to <n>
where <n> - Measurement gating
S - Single
R - Repeat
Examples:
BER G S
Set gating to Single
BER G R
Set gating to Repeat
BER M
BERT
Measurement
Status
Display current BERT measurement status in a specific style
BER [M <s>|?]
Examples:
BER M ?
Display style help
BER M N
N indicates Normal
BER M W
W indicates Wide
BER M CSV
CSV indicates Comma Separated Values