3
rd
Generation Compact RDMS
TM
Telemetry Receiver
25
Quasonix, Inc.
ACU [AGC [<p>|S <s>|T <n>]] - Antenna control unit AGC settings
<p> - Sets AGC output polarity to <p>
where: <p> - Polarity
{0|+} - Normal
{1|-} - Inverted
S <s> - Sets AGC output scale to <s>, 1.0 to 50.0 dB/V
T <n> - Sets manual mode AGC time constant to <n>, 0.1 to 1000.0 ms
Examples:
ACU
Report ACU related status
PCMFM$acu
ACU mode manual
AGC compensated AM on
Antenna scan type conical
Antenna scan rate 30.0 Hz
Manual AM bandwidth 100.0 Hz
Manual AGC time constant 100.0 ms
AM output po
AGC output po
AGC output scale 10.0 dB/V
AM scale 1.0
ACU AGC 0
Set polarity to Normal
ACU AGC 1
Set polarity to Inverted
ACU AGC S 42.0
Set AGC output scale to 42.0 dB/V
Valid range is 1.0 to 50.0 dB/V
ACU AGC T 222.0
Set manual mode AGC time constant to 222.0 ms
Valid range is 0.1 to 1000.0 ms
4.3.2.2
Adaptive Equalizer Control - AEQ
The AEQ command displays and controls adaptive equalizer settings.
AEQ [<e>|T <e>|M <c>|H <t>|R {<e>|S <s>}|C {<e>|R <r>}]
<e> - Sets adaptive equalizer enable to <e>
where: <e> - Enable
0 - Disabled
1 - Enabled
T <e> - Sets equalizer information tracking display to <e>