3
rd
Generation Compact RDMS
TM
Telemetry Receiver
33
Quasonix, Inc.
Valid range is 0.000 to 5.464 µs
AGC L S 1.987
Set AGC sample time to 0.567 µs
Valid range is 0.000 to 2.732 µs
AGC L A 42.000
Set AGC averaging sample time to 42.000 ms
Valid range is 0.002 to 2100.897 ms
AGC L D 0.0010
Set AGC deadband to 0.0010 dB
Valid range is 0.0000 to 15.9375 dB
AGC L C 25.000
Set AGC time constant to 25.000 ms
Valid range is 0.100 to 1000.000 ms
AGC L T -70.0
Set AGC power target to -70.0
Valid range is -100.0 to 13.0 dBm
4.3.2.4.5 Automatic Gain Control Attenuator Look Up Table - AGC LUT
The
AGC LUT
command displays or rebuilds the attenuator look up table.
AGC LUT [<p>|R]
- AGC attenuator Look Up Table
<p> - Show AGC LUT <p> attenuation
R - Rebuild AGC LUT
Examples:
AGC LUT 111.5 Display AGC look up table 111.5 attenuation
Valid range is 0.0 to 255.5 dB
AGC LUT R
Rebuild AGC look up table
4.3.2.4.6 Automatic Gain Control Auto Zero - AGC AZ
The
AGC AZ
command enables or disables AGC auto zero and sets hold threshold or time constants.
AGC [AZ [H <t>|T <t>]]
H <t> - Sets the AGC DSP auto zero hold threshold to <t>, -30.000 to 100.000 dB SNR
TR <c> - Sets the AGC DSP auto zero raising time constant to <c>, 0.050 to 100.000 seconds
TL <c> - Sets the AGC DSP auto zero lowering time constant to <c>, 0.050 to 100.000 seconds
Examples:
AGC AZ 0
Disable AGC auto zero
AGC AZ 1
Enable AGC auto zero
AGC AZ H 20.000
Set AGC DSP auto zero hold threshold to 20.000 dB
Valid range -30.000 dB to 100.000 dB
AGC AZ T 0.100
Set AGC DSP auto zero time constant to 0.100 seconds
Valid range 0.050 seconds to 100.000 seconds
4.3.2.4.7 Automatic Gain Control Zero - AGC Z
The
AGC Z
command sets the AGC Zero operating mode and the value at which zero can be set.