3
rd
Generation Compact RDMS
TM
Telemetry Receiver
21
Quasonix, Inc.
Mnemonic
Name
Description
Option (s)
Required
Mode
Restriction
CP
Clock Polarity
Report or set clock polarity
inversion state
Standard
For Asynch
PSK (legacy)
modes, CP A
and CP B must
be specified
separately
DA
Downconverting
Antenna
Displays and controls
receiver C band to P band
downconverting antenna
P band
enabled
receiver
None
DD
Differential
Decoding
Enable or disable differential
decoding
Standard
SOQPSK
DHO
High Speed
Digital Output
Displays and controls high
speed digital output settings
Standard
None
DLO
Low Speed
Digital Output
Displays and controls low
speed digital output settings
Standard
None
DOM
Digital Output
Muting
Control shut down of clock
and data outputs
Standard
None
DP
Data Polarity
Report or set data polarity
inversion state
Standard
For Asynch
PSK (legacy)
modes, DP A
and DP B must
be specified
separately
DQE
Data Quality
Encapsulation
Displays and controls data
quality encapsulation
Standard
ARTM modes
DQM
Data Quality
Metric
Display and control data
quality metric settings
Standard
ARTM modes
DR
Derandomizer
State
Report or set the
derandomizer state
Standard
None
DSO
Digital Status
Output
Controls the source, polarity,
and override states
Standard
None
FEC
Forward Error
Correction Mode
Report FEC status for
enabled modes
-K7
Legacy PSK
FL
Force Lock
Indication
Diagnostic tool to force the
system to indicate locked or
unlocked
Standard
None
FM
FM Demodulator
Settings
Displays and controls FM
demodulator settings
Standard
PCM/FM
FR
Frequency
Report or set receiver center
frequency
Standard
None