4-19
22 June 2004
Configuring the Time and Date
You can configure the date and time for the RMU. The date
and time will be used in the RMU log file to report when
events occurred.
To configure the date and time
Step 1
Click the Configuration tab.
Step 2
Enter the date and time in the Date and Time area.
Step 3
Click Submit and review your changes (indicated
in red).
Step 4
Enter your password and click Confirm to
complete the procedure.
Synchronizing with an NTP Server
You can connect the RMU to a network time (NTP) server to
automatically set the time.
To synchronize with an NTP server
Step 1
Click the Configuration tab.
Step 2
In the Date and Time area, select ON from the
Synchronization with NTP Server
drop-down
menu.
Step 3
In the NTP Server IP Address field, enter the IP
address of the NTP server.
Step 4
In the Timezone field, enter the time zone deviation
for the NTP server. To get a list of timezone offsets,
click list of timezones.
Step 5
Click Submit and review your changes (indicated
in red).
Step 6
Enter your password and click Confirm to
complete the procedure.
Note
If using a time
server, the
Scalar 1000
synchronizes
with the RMU.
Summary of Contents for Scalar 1000
Page 1: ...Scalar 1000 Library Operator Guide...
Page 10: ...x Contents 6 00054 02 Rev A...
Page 20: ...xx Tables 6 00054 02 Rev A...
Page 22: ...1 2 About this Guide 6 00054 02 Rev A...
Page 32: ...2 2 System Description 6 00054 02 Rev A...
Page 45: ...Connectivity 2 15 22 June 2004 Figure 2 4 Indirect Fibre Channel Attachment...
Page 50: ...3 2 Safety 6 00054 02 Rev A...
Page 56: ...4 2 Operation 6 00054 02 Rev A...
Page 58: ...4 4 Operation 6 00054 02 Rev A Figure 4 1 Operator Panel 4X20 LCD Panel Speaker Vent...
Page 80: ...5 4 Menus and Commands 6 00054 02 Rev A...
Page 83: ...Using the Operator Panel Menu 5 7 22 June 2004 Figure 5 1 Operator Panel Directory Structure...
Page 226: ...6 2 Processing Media 6 00054 02 Rev A...