Ejecting Media
6-9
22 June 2004
Manually Removing Cartridges
There are two levels of access control. The first is a mechanical
lock which is manipulated by the key. The second is password
protection which is invoked by either the host SCSI Mode
Select
command, LCD Page Security option, or through the
Security option on the Operator Panel.
To manually remove media, follow this procedure.
If locks are enabled, all locks must be disabled before the
procedure will successfully work.
Step 1
If the password option is enabled, enter the
password.
Step 2
Use the Operator Panel to place the library
into the NOT READY state. Refer to Mode Dialog on
page 5-10.
The Accessor completes any current task and returns to
the home position.
Step 3
Using the key, unlock and open the library door.
Step 4
Remove the cartridge from the desired storage cell.
Step 5
Close and lock the door.
Step 6
Place the library in the READY state. Refer to Mode
Dialog on page 5-10.
Step 7
If the library does not perform an inventory within
one minute, execute a SCSI INITIALIZE
ELEMENT STATUS
or a library Operator Panel
Inventory
command.
STATIC
SENSITIVE
Caution
Summary of Contents for Scalar 1000
Page 1: ...Scalar 1000 Library Operator Guide...
Page 10: ...x Contents 6 00054 02 Rev A...
Page 20: ...xx Tables 6 00054 02 Rev A...
Page 22: ...1 2 About this Guide 6 00054 02 Rev A...
Page 32: ...2 2 System Description 6 00054 02 Rev A...
Page 45: ...Connectivity 2 15 22 June 2004 Figure 2 4 Indirect Fibre Channel Attachment...
Page 50: ...3 2 Safety 6 00054 02 Rev A...
Page 56: ...4 2 Operation 6 00054 02 Rev A...
Page 58: ...4 4 Operation 6 00054 02 Rev A Figure 4 1 Operator Panel 4X20 LCD Panel Speaker Vent...
Page 80: ...5 4 Menus and Commands 6 00054 02 Rev A...
Page 83: ...Using the Operator Panel Menu 5 7 22 June 2004 Figure 5 1 Operator Panel Directory Structure...
Page 226: ...6 2 Processing Media 6 00054 02 Rev A...