Setup Menu
5-89
22 June 2004
Advanced Dialog
Path:
Main Menu
Setup Menu
Advanced Dialog
Use the
Advanced Dialog
to enable or disable the
automatic configuration, calibration, or cartridge scan when
the library power has been cycled. See Figure 5-119.
If Auto Inventory is disabled, the element status is not
known until the host issues an Initialize Element Status
command or an Inventory is performed via the Operator
Panel.
If Auto Inventory is enabled, an automatic cartridge
inventory is executed on each power cycle.
Any changes in the Operating Mode parameter value should
be made by authorized Service Personnel.
The default is set to 02.
Figure 5-119
Advanced Dialog
Parameter
Value
Auto Teach
Y
to enable Auto Teach for
automatic configuration and
calibration on each power
cycle
N
to disable Auto Teach on
each power cycle
Auto Inventory
Y
to enable Auto Inventory for
automatic cartridge scanning
inventory on each power cycle
N
to disable Auto Inventory on
each power cycle
Operating Mode
0
to select no library initiated
UNLOAD
command before a
move.
1
to select a three second delay
before a Get operation is
performed on a SDLT/DLT
drive after detecting that a tape
Auto Teach
:
Y<
Auto Inventory:
Y
Operating Mode:
02
Accept: N
Summary of Contents for Scalar 1000
Page 1: ...Scalar 1000 Library Operator Guide...
Page 10: ...x Contents 6 00054 02 Rev A...
Page 20: ...xx Tables 6 00054 02 Rev A...
Page 22: ...1 2 About this Guide 6 00054 02 Rev A...
Page 32: ...2 2 System Description 6 00054 02 Rev A...
Page 45: ...Connectivity 2 15 22 June 2004 Figure 2 4 Indirect Fibre Channel Attachment...
Page 50: ...3 2 Safety 6 00054 02 Rev A...
Page 56: ...4 2 Operation 6 00054 02 Rev A...
Page 58: ...4 4 Operation 6 00054 02 Rev A Figure 4 1 Operator Panel 4X20 LCD Panel Speaker Vent...
Page 80: ...5 4 Menus and Commands 6 00054 02 Rev A...
Page 83: ...Using the Operator Panel Menu 5 7 22 June 2004 Figure 5 1 Operator Panel Directory Structure...
Page 226: ...6 2 Processing Media 6 00054 02 Rev A...