Troubleshoot/Problem Solving 121
QXS-G2-312/324 Chassis RAID Chassis Controller LEDs
provides an illustration of the RAID chassis controller LEDs. This is a representative
example of the controller LEDs.The controller is identical in the QXS-G2-312 and QXS-G2-324 systems
(2 host ports).
Figure 101
CNC (FC and 10GbE SFPs) Controller LEDs
Off
On
Power control circuit failure
Off
On
RAID array status
The events in which the controller can set this notification are:
•
Disk group rebuild in progress
•
Disk group consistency check
•
Do not remove device
•
Disk in failed disk group
•
Aborted disk group reconstruction
Table 14
2U Drive LED States
Drive LED
(Green)
Drive LED
(Amber)
Status
4
5
6
7
9
2
2
2
10
10
2
1
8
3
1 1
1
LED
Description
Definition
1
Host 4/8/16Gb FC
1
Link
Status/Link Activity
Off — No link detected.
Green — The port is connected and the link is up.
Blinking green — The link has I/O or replication activity.
2
Host 10GbE iSCSI
2,3
Link Status/Link
Activity
Off — No link detected.
Green — The port is connected and the link is up.
Blinking green — The link has I/O or replication activity.
3
OK
Green — The controller is operating normally.
Blinking green — System is booting.
Off — The controller module is not OK, or is powered off.
4
Fault
Off — The controller is operating normally.
Amber — A fault has been detected or a service action is required.
Blinking amber — Hardware-controlled power-up or a cache flush or restore
error.
Summary of Contents for QXS G2 Series
Page 1: ...QXS G2 Hardware Installation and Maintenance Guide 12 24 and 84 Drive Systems 6 68649 01 Rev A...
Page 126: ...114 QXS G2 Hardware Installation and Maintenance Guide...
Page 176: ...164 QXS G2 Hardware Installation and Maintenance Guide...
Page 232: ...220 QXS G2 Hardware Installation and Maintenance Guide...
Page 236: ...224 QXS G2 Hardware Installation and Maintenance Guide...
Page 246: ...234 QXS G2 Hardware Installation and Maintenance Guide...