General Description and Specifications
1-12
Quantum DLT 8000 Tape System
1.3.13 Current Requirements
Table 1-11 presents the current requirements for the tape system in a variety of operating
conditions. These numbers may vary with workload.
Table 1
−
11 Current Requirements
Drive Operating in WRITE Mode Start/Stop
Typical
Maximum (Includes Ripple)
5 Volt
2.2
3.9
12 Volt
1.2
3.6
Drive Operating in Calibration
Typical
Maximum (Includes Ripple)
5 Volt
2.1
3.3
12 Volt
1.2
4.5
Drive Tensioned, but Tape Not in Motion (Standby Mode)
Typical
Maximum (Includes Ripple)
5 Volt
2.2
2.7
12 Volt
0.6
1.0
Drive Unloaded with Cartridge Door Opened
Typical
Maximum (Includes Ripple)
5 Volt
2.1
2.6
12 Volt
0.6
1.1
Drive Rewinding to BOT
Typical
Maximum (Includes Ripple)
5 Volt
2.3
3.6
12 Volt
0.8
3.0
Drive Operating in Stream WRITE/READ Mode
Typical
Maximum (Includes Ripple)
5 Volt
3.1
4.3
12 Volt
1.0
3.6
Summary of Contents for DLTtape DLT 8000
Page 1: ...DLTTM 8000 Tape System Product Manual Nov 10 2003 81 60118 06...
Page 5: ...USER MANUAL STATEMENTS FOR CLASS B EQUIPMENT continued...
Page 6: ......
Page 26: ...Table of Contents xxiv Quantum DLT 8000 Tape System...
Page 36: ...About This Manual Quantum DLT 8000 Tape System xxxii...
Page 54: ...General Description and Specifications 1 18 Quantum DLT 8000 Tape System...
Page 102: ......
Page 372: ......
Page 376: ...Appendix A Definition of Vendor Unique Sense Data Information A 4 Quantum DLT 8000 Tape System...
Page 386: ...Appendix C Updating the Firmware C 6 Quantum DLT 8000 Tape System...
Page 396: ...Appendix E Visual Inspection Procedure for DLTtape Cartridges E 8 Quantum DLT 8000 Tape System...
Page 406: ...Appendix G DLT 7000 Emulation Feature G 8 Quantum DLT 8000 Tape System...
Page 407: ......