SCSI Commands
Quantum DLT 8000 Tape System
5-199
REQUEST SENSE Command (03h) (continued)
Table 5
–
89 Supported ASC / ASCQ in Hex (continued)
Sense Key
ASC
ASCQ
Meaning
0Bh COMMAND
ABORTED
43
00
Message Error
44
80
Unexpected Selection Interrupt
44
82
Command Complete Sequence Failure
44
83
SCSI Chip, Gross Error/ Illegal – Command Status
44
84
Unexpected/Unexplained Residue Count in Transfer
Register
44
87
Disconnect Sequence Failed
44
89
Internal Target Failure
45
00
Select/Reselect Failure
47
00
SCSI Parity Error
48
00
IDE Message Error
49
00
Invalid Message Error
4B
00
Data Phase error
4E
00
Overlapped Commands Attempted
83
00
Can not retry read/write data transfer
0Dh VOLUME
OVERFLOW
(No Additional Sense Code or Sense Code Qualifier)
0Eh MISCOMPARE
(No Additional Sense Code or Sense Code Qualifier)
Summary of Contents for DLTtape DLT 8000
Page 1: ...DLTTM 8000 Tape System Product Manual Nov 10 2003 81 60118 06...
Page 5: ...USER MANUAL STATEMENTS FOR CLASS B EQUIPMENT continued...
Page 6: ......
Page 26: ...Table of Contents xxiv Quantum DLT 8000 Tape System...
Page 36: ...About This Manual Quantum DLT 8000 Tape System xxxii...
Page 54: ...General Description and Specifications 1 18 Quantum DLT 8000 Tape System...
Page 102: ......
Page 372: ......
Page 376: ...Appendix A Definition of Vendor Unique Sense Data Information A 4 Quantum DLT 8000 Tape System...
Page 386: ...Appendix C Updating the Firmware C 6 Quantum DLT 8000 Tape System...
Page 396: ...Appendix E Visual Inspection Procedure for DLTtape Cartridges E 8 Quantum DLT 8000 Tape System...
Page 406: ...Appendix G DLT 7000 Emulation Feature G 8 Quantum DLT 8000 Tape System...
Page 407: ......