background image

Page 27

 

March 27, 2008

4100-I  ACT WOOD INSERT

250-7201  Rev D

R

Lifetime Warranty

LIMITED LIFETIME WARRANTY

The Hearth & Home Technologies limited Lifetime Warranty guarantees that the following components will work as designed for the life-
time of the stove or Hearth & Home Technologies will repair or replace them.  These items include but are not limited to steel and cast 
iron components, all gas burners, gas logs, combustion chambers, heat exchanger systems, stainless steel fi rebox components, plating, 
doors, glass damaged by thermal breakage, steel baffl e supports, steel and ceramic baffl es and manifold tubes. Labor is for the fi rst fi ve 
years.

THREE YEAR WARRANTY

Our pellet fi repots are covered under Hearth & Home Technologies three-year warranty program.  Labor is for 3 years.

TWO YEAR WARRANTY

All electrical components such as but not limited to blowers, wiring, vacuum switches, speed controls, control boxes, thermodisc switches,  
pilot assembly, gas valves, thermostats and remotes are covered under Hearth & Home Technologies two-year warranty program.  Effec-
tive April, 2005 igniters are also covered under the two year warranty.  Labor is for two years.

ONE YEAR WARRANTY

Porcelain and Powder Coat fi nishes are warranted against manufacturer defects for one year.  Labor to repair or replace these parts is 
covered for one year, reimbursed per our warranty service fee schedule.

CONDITIONS

This warranty is non-transferable and is made to the original retail purchaser only provided that the purchase was made through an 
authorized dealer of Hearth & Home Technologies. It must be installed and operated at all times in accordance with the Installation and 
Operating Instructions furnished with this product, as well as any applicable local and national codes.  Any alteration, willful abuse, ac-
cident, or misuse of the product shall nullify this warranty.

Labor to repair or replace items covered under the limited Lifetime Warranty will be covered for the fi rst fi ve years per our warranty ser-
vice fee reimbursement schedule.  Parts covered under the limited Lifetime Warranty will be covered for the lifetime of the appliance up 
to a maximum of ten (10) years after Hearth & Home Technologies discontinues the model and two (2) years for optional accessories.  
Adjustments, regular maintenance, cleaning and temporary repairs do not qualify for a service call fee and will not be covered.  The re-
placement of consumer replaceable items and installation of upgraded component parts do not quality for a service call fee, and will not 
be covered.

This limited Lifetime Warranty does not extend to or include surface fi nish on the appliance, door gasketing, glass gasketing, glass, fi re-
brick, pellet logs, kaowool or other ceramic insulating materials.  It does not cover installation or operational-related problems such as 
overfi ring, use of corrosive driftwood, downdrafts or spillage caused by environmental conditions, nearby trees, buildings, hilltops, moun-
tains, inadequate venting or ventilation, excessive offsets, or negative air pressures caused by mechanical systems such as furnaces, 
fans, clothes dryers, etc.

Any installation, construction, transportation, or other related costs or expenses arising from defective part(s), repair, replacement, etc., 
will not be covered by this warranty, nor will Hearth & Home Technologies assume responsibility for them.  Further, Hearth & Home 
Technologies will not be responsible for any incidental, indirect, or consequential damages, except as results in damage to the interior 
or exterior of the building in which this appliance is installed.  This limited Lifetime Warranty does not apply to the venting components, 
hearth components or other accessories used in conjunction with the installation of this product not manufactured by Hearth & Home 
Technologies

This warranty is void if the stove has been overfi red or operated in atmospheres contaminated by chlorine, fl uorine, or other damaging 
chemicals, the stove is subjected to prolonged periods of dampness or condensation, or there is any damage to the stove or other compo-
nents due to water or weather damage which is the result of, but not limited to, improper chimney or venting installation.  Hearth & Home 
Technologies may, at its discretion, fully discharge all obligations with respect to this warranty by either repairing or replacing the unit, or 
refunding the wholesale price of the defective part(s).

This limited Lifetime Warranty is effective on all appliances sold after May 1, 2002 and supersedes any and all warranties currently in 
existence.

Policy 250-8620  Rev K

Summary of Contents for 4100I-GD-B

Page 1: ...ogy ACT O T O T L Tested and Listed by Beaverton Oregon USA OMNI Test Laboratories Inc C US 250 7201D March 27 2008 1445 North Highway Colville WA 99114 2008 R Installation and service of this applian...

Page 2: ...LES LABEL LOCATION Back side of left side panel Manufactured Date Serial Number Model Name Test Lab Report No Model 4100 I 4100 I INSERT INSERT Serial No Num ro De S rie O T O T L Tested and Listed by...

Page 3: ...o Chimney Ring 13 PARTS ACCESSORY INSTALLATION Outside Air Installation 13 Panel Sets and Trim Sets 14 Blower Cord Installation 15 Blower Control Box with Switch 15 Fan Blower Replacement 15 Zero Clea...

Page 4: ...MENSIONS TOP VIEW SIDE VIEW FRONT VIEW 20 7 8 530mm 30 o 10 7 8 276mm 21 5 8 549mm 7 7 8 200mm 16 1 4 413mm C L 24 610mm 30 762mm 12 1 8 308mm 9 5 16 135mm 45 3 4 1162mm A B 30 7 8 784mm 44 3 4 1137mm...

Page 5: ...kness k value 0 84 or equivalent material Zero Clearance Installations USA Only Omni Report 061 S 40 2 In Canada a full length six inch 152mm S635 flue liner required as per ULC S628 CLEARANCES TO COM...

Page 6: ...RECOMMENDATIONS These installation instructions describe the installation and operation of the Quadra Fire 4100 I Wood Insert This insert meets the U S Environmental Protection Agency s 1990 particul...

Page 7: ...ue is convenient when more than one material is used since you can add the R values together whereas you can not do this for k value The HIGHER the R factor means less heat is being conducted through...

Page 8: ...f or structure that is within10 feet 305cm of the chimney measured hori zontally Refer to Figure 8C CHIMNEY REQUIREMENTS Non combustible fire stopping material Minimum 2 inch 51mm clearance from combu...

Page 9: ...ust be followed precisely 7 Use silicone to create an effective vapor barrier at the location were the chimney or other component penetrates to the exterior of the structure 8 Follow the chimney and c...

Page 10: ...hould also be checked to ensure it meets the minimum standard of the National Fire Protection Association NFPA Standard 211 The following bullets list the more critical requirements for a properly con...

Page 11: ...ly attached to the insert flue collar and the chimney top To prevent room air passage to the chimney cavity of the fireplace seal either the damper area around the chimney liner with high temperature...

Page 12: ...up on uneven material when sliding the insert into place See Figure 12B Figure 12A Figure 12B INSTALLATION IN CANADA MASONRY and HEAT CIRCULATING INSTALLATIONS INTO FACTORY BUILT FIREPLACES ARE PROHIB...

Page 13: ...4 NOTE Tabs are shipped from factory in a flat position Bend upwards 90 degrees Figure 13A Tools Needed Phillips Head Screwdriver 1 Remove three screws and cover plate from back side of insert Save t...

Page 14: ...sert with 8 32 sheet metal screws through tabs on bottom lower inside corners on side panels Figure 13B Included in Panel Kit 2 side panels left and right 1 panel top 2 trim pieces 1 trim top 1 fasten...

Page 15: ...wards you See Figure 15D 2 Loosen 4 screws 2 on each side of the motor that secures motor to the housing Remove the motor See Figure 15E 3 Attach new motor using the same screws to the blower housing...

Page 16: ...r top lip and into position on scis sors Place side pieces on first and then front piece The front piece overlaps side pieces NOTE The trim in the Flush Mount Kit is one piece 7 Once you are satisfied...

Page 17: ...OPERATION Before lighting your first fire in the insert make certain that the baffle is correctly positioned It should be resting against the rear support Also refer to care and cleaning of plated su...

Page 18: ...especially important to fully open both controls when reload ing the insert as failure to do so could result in excessive emissions also referred to as opacity After a wood load has been burning on hi...

Page 19: ...irst 5 to 15 minutes Second Stage The next stage of burning the secondary stage is the period when the wood gives off flammable gases which burn above the fuel with bright flames During this stage of...

Page 20: ...entering of glass in door and or side frames and give all screws a final tightening CREOSOTE FORMATION AND NEED FOR REMOVAL When wood is burned slowly it produces tar and other organic vapors which co...

Page 21: ...ceramic blanket from above the baffle 3 With a 3 16 Allen wrench remove 2 front manifold tube retainer bolts on the air channel under the end of the front tubes NOTE Soak the bolts with penetrating o...

Page 22: ...em Description 1 Ashcatcher 8 Baffle Fiberboard 15 Flue Tab 2 Blower 180 cfm 9 Ceramic Blanket 1 2 16 Top Cast 3 Blower Mount Base 10 Door Latch Box Assembly 17 Brick 2 with holes 4 Blower Housing Cas...

Page 23: ...ual Touch up Paint Warranty Card Door Handle 2 Screws Permanent Label If Fireplace Altered 435 5310 19 Door Assembly with Glass Gold 435 5190 19 Door Assembly with Glass Nickel 435 5300 19 Door Assemb...

Page 24: ...w SP BB3044 GD Panel Trim Set Nickel Small 30 1 2 h x 44 5 8 w SP BB3044 NL Zero Clearance Trim Support Adjustable 9 d x 45 w 2 10 high 841 0990 Zero Clearance Trim Support Adjustable 12 d x 50 w 2 10...

Page 25: ...Page 25 March 27 2008 4100 I ACT WOOD INSERT 250 7201 Rev D R Date of Service Performed By Description of Service Service and Maintenance Log...

Page 26: ...4100 I ACT WOOD INSERT Page 26 March 27 2008 R 250 7201 Rev D Consumer s Notes...

Page 27: ...ome Technologies discontinues the model and two 2 years for optional accessories Adjustments regular maintenance cleaning and temporary repairs do not qualify for a service call fee and will not be co...

Page 28: ...B2 6729551 6736133 6748940 6748942 D320652 D445174 D462436 Canada 1297749 2195264 2225408 or other U S and foreign patents pending Hearth Home Technologies 1445 North Highway Colville WA 99114 Divisio...

Reviews: