Page 15
March 27, 2008
4100-I ACT WOOD INSERT
250-7201 Rev D
R
BLOWER CORD LOCATION & BLOWER
CONTROL BOX WITH SWITCH
Remove Bolt
Remove Bolt
Remove 4 screws, lift
motor from housing
This insert comes standard with a blower, installed at the
factory with blower cord on right side of insert (as you face
the unit). The blower cord can also be installed on the left
side. Disconnect the cord from right side.
ROUTE WIRES IN
FRONT OF FAN
.
Re-install on the left side. Do not route cord
behind the cooling fan.
Figure 15B - Right Side Location
FAN (BLOWER) REPLACEMENT
Included in Kit:
Replacement Blower
Tools Needed
: 5-32 Wrench and Phillips Head Screwdriver.
1. Remove bolts from both sides of the insert and slide the
lower cast cover towards you.
See Figure 15D
2. Loosen 4 screws (2 on each side of the motor) that
secures motor to the housing. Remove the motor.
See
Figure 15E.
3. Attach new motor using the same screws to the blower
housing.
4. Re-attach lower cast cover to insert using the bolts
removed in Step 1.
Figure 15E
Figure 15D
Black
Red
White
Snap Disc
Blower Control
Box with Switch
Cooling Fan
Black
HIGH OFF
LOW
FAN
AUTO
MANUAL
MANUAL: Over-rides
the internal Snap Disc
AUTO: Fan will
turn ON/OFF
automatically and
is controlled by the
internal Snap Disc
Figure 15A
Operating the Blower Control Box with Switch
1. The blower will turn on/off automatically when set to AUTO.
2. When set to MANUAL, the fan will turn on/off only when you
turn it on or off. This setting over-rides the internal snap
disc.
3. Adjust the speed of the fan by turning the HIGH/LOW knob
to the desired setting.
Black
Red
White
Snap Disc
Cooling Fan
Figure 15C - Left Side Location