Serial
Communication
4-9
Administration/Communications Submenu
value is 1 bit. Set this option to match the number of stop bits trans-
mitted by the host.
Hdwe Flow Ctl
The Hdwe Flow Ctl (Hardware Flow Control) option allows you to pick
the type of hardware flow control used by your host. The choices are
DSR POL (default value: Lo), DSR (default value: Off), DTR POL
(default value: Lo), DTR (default value: On), RTS (default value: Off),
and CTS (default value: Off).
If your host uses hardware flow control, set this option to match the
type used by the host.
PS Protocol
This option sets the binary communications protocol (BCP) for com-
municating over a serial, parallel, or optional network interface to a
PostScript printer. Binary communications protocol allows any 8-bit
binary value (0-255) to be treated as data, while allowing a few of the
values to function as special control characters. When communicat-
ing 8-bit binary data in Binary or Binary Fixed mode, the printer uses
the quoting mechanism of the BCP to distinguish between the special
control characters and print job binary data.
To differentiate data from the special control characters, any data that
is the same as one of the following special control characters must be
quoted:
ASCII
Keyboard
ASCII
Name
ASCII
Hex Value
Control
Function
^A
SOH
0x01
Quote data character
^C
ETX
0x03
Abort job and flush to end of file
^D
EOT
0x04
End-of-file marker
^E
ENQ
0x05
(Reserved for future use)
^Q
DC1
0x11
XON in XON/XOFF flow control
^S
DC3
0x13
XOFF in XON/XOFF flow control