Page 8
System Option 1. The system may be configured for use with the following:
Double Pole Zones:
This is a normally closed zone configuration without end of line resistor.
Double End of Line Zones: This configuration uses end of line resistors which allow both zone and
tamper circuits on the same zone connection.
User Log Reset Enable:
This option allows the user to reset the system log by entering
User Log Reset Disable: By selecting this option only the engineer has the ability to reset the system
log.
Tone Dial:
Select this option for telephone exchanges using tone dial technology.
Pulse Dial:
Select this option for telephone exchanges using pulse dial technology.
Internal & External Sounders
On Tamper Activation:
This option will cause both internal and external sounders to activate on
a tamper alarm when the panel is in day mode.
Internal Sounder Only On
Tamper Activation:
This option will cause only the internal sounder to activate upon a tamper
alarm when the panel is in day mode.
System Option 2. The system may be configured for use with the following:
7 Day Test Dial:
Dials the Central Monitoring Station every 7 days.
24 Hour Test Dial:
Dials the Central Monitoring Station every 24 hours.
Dial In:
This option will allow the Atlas 8 to respond to an incoming call in answer
machine compatible mode.
Answer machine compatible mode: This provides a way of using the Atlas
on the same line as an answering machine. The default setting is AMC on.
To remotely access the Atlas in AMC mode dial in and wait for a single
ring, then hang up and wait for at least 10 seconds, but no more than 40,
then dial back in. The Atlas will now answer instantly.
No Dial In:
This option will cause the Atlas 8 to ignore incoming calls. The master user
may generate a one hour time window to allow up/downloading by using
the function. If this option is selected - this will answer on a single ring.
Wide handshake filters: Gives a greater chance of the handshake from central station being
recognised, use only if the panel does not transmit data after the correct
handshake sequence has been transmitted by the central station.
Standard handshake
This setting is the default and will more reliably detect the correct
filters:
handshake
Silent P.A. Zones:
The P.A. zone activation will not generate internal or external sounders if
this option is selected. Dial out will occur however if the panel has been
programmed
to
do
so.
Audible P.A. Zones:
The Personal Attack zone activation will cause both internal and external
sounders to operate. Dial out will also occur if the panel has been
programmed to do so.
System Option 3. The system may be configured for use with the following:
Engineer Code Lock
N.V.M Reset:
This option allows the control panel programmable settings to be reverted
back to factory default when in Engineer mode only.
Engineer Power Up
N.V.M Reset:
This allows the control panel programmable settings to be reverted back to
factory
default
when
in
User
Mode.