Rins171 Issue 6
Page 29
13 TECHNICAL
SPECIFICATION
13.1 Power
supply
Power input
: 17V a.c.
Low voltage output
: 13.2 Vdc fused, 1.25 Amp maximum Including Control Panel.
1Amp maximum available for external devices.
Low voltage output fuses
: 1 Amp quick blow.
Battery charge voltage
: 13.7 V d.c.
Rechargeable battery capacity
: 12V sealed lead acid, 2.8 to 6 AH.
13.2 Control
PCB
Current consumption
(day mode)
: 130mA.
(set
mode)
:
130mA.
(alarm)
:
130mA.
Auxiliary DC output supply
: Regulated 13.2V d.c. for use with PIR, microwave and shock sensors.
Extension Speaker load
: 16 to 32 Ohms.
Bell
:
500mA.
Strobe
:
500mA.
PR1 / PR2
: 250mA.
Alarm bell time
: 2 to 20 minutes (software programmable).
Zone type
: Normally closed loops which activate when opened or short circuit.
Zone loop current
: 0.76 to 1.03mA.
Zone activation resistance
: 6.9K Ohms (minimum).
Zone loop activation timer
: 0.35 seconds.
Exit timer
: 2 to 255 seconds.
Entry
timer
:
2
to
255
seconds.
13.3
Mechanical
Dimensions
: 228 x 243 x 75 mm.
Case material
: 1.2mm (0.8mm export) thick Mild steel with screw fixing front cover.
Colour
: White (grey export).
Weight excluding battery
: 2.6Kg.
13.4 Environmental
Operating temperature
: 0 to +40
0
C (+32 to +104
0
F).
Storage temperature
: -20 to +60
0
C (-4 to +172
0
F).
13.5
Cleaning
DO NOT use strong detergents to clean this control panel. To remove any dirt or grime, wipe with a clean damp cloth
ONLY
Summary of Contents for ATLAS 8
Page 35: ...Rins171 Issue 6 Page 35...
Page 36: ...Page 36...