Page 22
11.11.3 System Option 1
Enter
followed by
-
. The RKP display will toggle
✔
and X as the numbered keys are pressed,
indicating the selection made.
Key
Press
Display
1 2 3 4
Double Pole Zone
User
Log
Reset
Enabled
Pulse Dial
External and Internal
Sounders on Tamper
Activation
X
End Of Line Zones
User
Log
reset
Disabled
Tone Dial
Internal
Sounder
Only On Tamper
Press
to accept.
11.11.4 System Option 2
Enter
followed by
-
. The RKP display will toggle
✔
and X as the numbered keys are pressed,
indicating the selection made.
Key
Press
Display
1 2
3
4
7 Day test dial
Dial in
Wide handshake filters
Silent PA zones
X
24 Hour test dial
No dial in
Standard handshake filters
Audible PA zones
Press
to accept.
11.11.5 System Option 3
Enter
followed by
-
. The RKP display will toggle
✔
and X as the numbered keys are pressed,
indicating the selection made.
Key
Press
Display
1 2 3 4
Engineer code NVM
Reset only
Display open zones
in day mode
Alarm on line fail
Telephone line
monitoring disabled
X
Power down NVM
Reset
No display
No alarm on line fail
Telephone line
monitoring enabled
Press
to accept.
11.11.6 System Option 4
Enter
followed by
-
. The RKP display will toggle
✔
and X as the numbered keys are pressed,
indicating the selection made.
Key
Press
Display
1 2 3 4
Bell Squawk
Bell time seconds
No AC fail warning
Spare
X
No Bell squawk
Bell time minuets
AC fail warning
Spare
Press
to accept.
11.11.7 Programmable Re-sets
Enter
HQWHUVHTXHQFH
enter the number of re-sets required
-
(
= continuous re-setting)
Summary of Contents for ATLAS 8