Page 20
11.2
Entering Engineer Mode
To enter the Engineer Mode.
Enter
(Engineer Code, factory default to 9999)
Whilst in Engineer mode, you are able to remove any covers without creating a tamper alarm.
11.3
Setting Volume Control (Extension speaker only)
This volume is controlled via the adjustable volume pot on the main processor board.
1. Remove lid.
2. Set volume pot to desired volume
3. Depress a number digit on the keypad to check desired volume has been reached.
4. Replace cover.
In an alarm condition the volume control is overridden and the speakers will operate at full volume.
NOTE:
Each RKP has its own volume control pot.
11.4
Resetting the Non Volatile Memory (NVM) to Factory Settings
The panel may be programmed as power up NVM reset or engineer only NVM reset.
Power Up NVM Reset
If the panel is configured by the engineer to allow the reset of the NVM back to factory settings by powering up the
system with the NVM reset pins shorted together.
Locate the NVM reset pins on the PCB, using the link pin provided connect the two pins together. Power down the
system (mains and battery). Restore power and remove the link. The system is now back to factory default settings.
Engineer Only NVM Reset
If the panel is configured for Engineer Only NVM Reset, the panel can only be reset to factory defaults if the Engineers
code is known.
Enter the engineer mode. Use the link supplied to connect the NVM reset pins together and enter
on the
key pad, remove the link. The system is now back to factory default settings.
11.5
Setting the Panel when Mains Fails
Under normal operation the panel will indicate a fault condition if the AC supply is disconnected. It will still be possible to
Set and Unset the control panel during a mains fail and no further action is required.
Full functionality of the control panel is available during mains fail.
11.6
Programming Set Modes.
Any zone may be programmed to be any one of the following:
(QWU\([LW
$FFHVV
LPPHGLDWH
RPLW
PRPHQWDU\NH\
ODWFKHGNH\
WDPSHU
SHUVRQDODWWDFN
KRXUILUH
The attribute for each zone is changed by pressing
or
until the required attribute appears in the display.
When the display shows the required attribute press the
key to store the zone attribute. If the required attribute is
already shown press the
key to go to the next zone.
NOTE:
On pressing
after selecting the attribute for zone 8, the programme will be stored automatically.
To programme Set A enter
, to programme Set B enter
to programme Set C enter
and to programme Set D enter
.
Should you wish to view any zone status within a Set mode use the same procedure, but do not scroll the keys.
11.7
Setting the Alarm Bell Time
To adjust the alarm bell cut off time.
Enter
followed by the required time in minutes (
to
minutes) followed by
to accept.
Incorrect entry gives an audible error tone and correct entry gives three bleeps.
The alarm bell cut off time for the Atlas 8 is factory set to 20 minutes.