11.2 

 Entering Engineer Mode  

To enter the Engineer Mode. 

Enter 

  

  

 (Engineer Code, factory default to 9999) 

Whilst in Engineer mode, you are able to remove any covers without creating a tamper alarm. 
 
11.3 

Setting Volume Control (Extension speaker only) 

This volume is controlled via the adjustable volume pot on the main processor board. 
 

1. Remove lid. 

 

2. Set volume pot to desired volume 

 

3. Depress a number digit on the keypad to check desired volume has been reached. 

 

4. Replace cover. 

In an alarm condition the volume control is overridden and the speakers will operate at full volume. 
 
NOTE:

 Each RKP has its own volume control pot. 

 
11.4 

Resetting the Non Volatile Memory (NVM) to Factory Settings 

The panel may be programmed as power up NVM reset or engineer only NVM reset.  
 
Power Up NVM Reset 
If the panel is configured by the engineer to allow the reset of the NVM back to factory settings by powering up the 
system with the NVM reset pins shorted together. 
Locate the NVM reset pins on the PCB, using the link pin provided connect the two pins together.  Power down the 
system (mains and battery).  Restore power and remove the link.  The system is now back to factory default settings. 
 
Engineer Only NVM Reset 
If the panel is configured for Engineer Only NVM Reset, the panel can only be reset to factory defaults if the Engineers 
code is known. 

Enter the engineer mode.  Use the link supplied to connect the NVM reset pins together and enter 

 on the 

key pad,  remove the link.  The system is now back to factory default settings. 
 
11.5 

Setting the Panel when Mains Fails 

Under normal operation the panel will indicate a fault condition if the AC supply is disconnected. It will still be possible to 
Set and Unset the control panel during a mains fail and no further action is required.  
Full functionality of the control panel is available during mains fail. 
 
11.6 

 Programming  Set Modes.  

Any zone may be programmed to be any one of the following:   
 

(QWU\([LW

$FFHVV 

LPPHGLDWH

RPLW

PRPHQWDU\NH\ 

ODWFKHGNH\

WDPSHU 

SHUVRQDODWWDFN

KRXUILUH

 

The attribute for each zone is changed by pressing 

 or 

 until the required attribute appears in the display.  

When the display shows the required attribute press the 

 key to store the zone attribute.  If the required attribute is 

already shown press the 

 key to go to the next zone. 

 

NOTE: 

On pressing 

 

after selecting the attribute for zone 8, the programme will be stored automatically.

 

To programme Set A enter 

 , to programme Set B enter  

 

to programme Set C enter 

   and to programme Set D enter 

 
Should you wish to view any zone status  within a Set mode use the same procedure, but do not scroll the   keys.     
 
11.7 

Setting the Alarm Bell Time 

To adjust the alarm bell cut off time.  

Enter  

 

followed by the required time in minutes (

 to  

 minutes) followed by 

 to accept. 

Incorrect entry gives an audible error tone and correct entry gives three bleeps. 
The alarm bell cut off time for the Atlas 8 is factory set to 20 minutes. 
 

Summary of Contents for ATLAS 8

Page 1: ...Rins171 Issue 6 INSTALLATION INSTRUCTIONS Lcd Remote Keypad Pyronix Ltd MARCH 00 This Product is approved for use in the Residential Commercial and Light Industrial Environment...

Page 2: ...gn Pyronix reserve the right to amend specifications without giving prior notice A copy of our warranty can be obtained from the above address 3 URQL LPLWHG 3 URQL RXVH UDLWKZHOO D HOODE 5RWKHUKDP 6 4...

Page 3: ...ons 16 10 8 Powering Up The panel 16 10 9 Atlas Double Pole Wiring Diagram 17 10 10 Atlas End of Line Wiring Diagram 18 11 PROGRAMMING 19 11 1 Factory Defaults 19 11 2 Entering Engineer Mode 20 11 3 S...

Page 4: ...eporting Codes 25 11 17 Digicom Codes 26 11 18 Keyswitch Set Configuration 26 11 19 Group Reporting Telephone Allocation 26 11 20 Engineer NVM Reset 27 11 21 Follow Select 27 11 22 Exiting Engineer Mo...

Page 5: ...g 3 2 Master User Level Enables All Limited User facilities 4 Clearing of event log if allowed by the Engineer 5 Omitting zones 6 Alteration of both Limited and Master User codes 7 LED Strobe Bell Ext...

Page 6: ...try Exit zone then an alarm will be generated immediately Immediate This is a zone which will when triggered wil create an alarm when the panel is set Omit If a zone is programmed as an Omitted zone b...

Page 7: ...Walk test The walk test function allows each of the Set modes to be checked in order to verify that all the intruder detectors on the alarm system are functioning correctly When undergoing a walk test...

Page 8: ...tlas on the same line as an answering machine The default setting is AMC on To remotely access the Atlas in AMC mode dial in and wait for a single ring then hang up and wait for at least 10 seconds bu...

Page 9: ...igit access code required by the alarm company in order to access the Atlas 8 during an uploading or downloading operation Reporting Codes These are unique two digit or single digit numbers used by th...

Page 10: ...will also emit a short duration of sound upon disarming Default value OFF Bell Time Minutes Seconds This option allows for very short bell durations Default value Minutes AC Fail Delay This option del...

Page 11: ...carefully Plan out the various areas and degrees of protection required from each zone It is important to decide which type each zone should be if selective sets are to be used Work out the cable rou...

Page 12: ...kaging containing the control panel and PCB Push in the PCB support posts from the rear of the panel as shown If required assemble the tamper switch from the optional kit of parts as indicated If nece...

Page 13: ...l mounting hole using one of the screws and plugs from the screw pack If possible use a spirit level or some other means to position the control panel squarely then drill two more holes into the wall...

Page 14: ...ed BAT on the PCB Battery Positive Battery Negative 10 3 Bell Strobe and Extension Speaker Connections Bell Positive Bell Trigger Strobe Positive Strobe Negative Speaker Positive Speaker Negative NOTE...

Page 15: ...r external sounder 0 050 Single remote keypad 0 015 Required capacity for alarm condition 0 815 x 0 333 0 271 Ahrs Capacity required for standby 7hrs 40 mins 7 67 hrs Non alarm current for control pan...

Page 16: ...to protect all the zone tamper wiring Up to ten sensors or door contacts may be wired on each zone 10 7 Telephone Connections T 1 R 1 TIP RING 10 8 Powering Up Your Panel RKP a Connect the battery lea...

Page 17: ...7 7 1 7 7 1 H J 0 0 7 2 1 9 1 5 2 2 0 7 7 5 5 5 3 521 3 5 7 0 3 5 5 0 6 8 3 3 3 521 3 5 7 7 67 5 0 6 3 5 1 6 3 H J 6 6 2 1 7 0 3 5 5 0 6 8 3 3 7 1 6 2 1 6 3 5 2 3 7 2 1 7 7 5 7 7 5 5 6 7 2 7 3 2 1 6 6...

Page 18: ...5 6 7 2 7 3 2 1 6 6 7 0 3 7 0 3 5 2 1 1 7 2 1 6 6 2 8 5 7 2 2 1 3 5 2 5 0 0 2 5 7 0 3 5 7 3 2 1 1 7 2 5 5 3 6 3 H J 6 6 2 1 H J 0 0 7 2 1 9 1 5 2 2 0 7 1 6 2 1 6 3 5 2 3 7 2 1 2 3 7 2 1 6 5 1 9 0 1 7...

Page 19: ...d Of Line Resistor Programmable Outputs Off System Option 1 End Of Line Zone User Log Reset Disabled Tone Dial Internal Sounder Only On Tamper Activation System Option 2 24 Hour Test Dial Dial In Spar...

Page 20: ...mode Use the link supplied to connect the NVM reset pins together and enter on the key pad remove the link The system is now back to factory default settings 11 5 Setting the Panel when Mains Fails Un...

Page 21: ...e new Engineer Code gives an audible acceptance tone then the new Engineer Code again gives an audible acceptance tone If an incorrect key is entered an error tone will be given and the function ended...

Page 22: ...ard handshake filters Audible PA zones Press to accept 11 11 5 System Option 3 Enter followed by The RKP display will toggle and X as the numbered keys are pressed indicating the selection made Key Pr...

Page 23: ...ically when the last digit is entered 11 14 Customer Account Code Issued by Central Monitoring Station Enter HQWHU VHTXHQFH followed by the 4 digit code e g 4 digit 11 15 Downloading Access Code Enter...

Page 24: ...set reporting codes To disable an event insert blanks by pressing the key in place of the two digits Examples Set A Set B Set C Set D Duress Set Duress Unset Confirmed alarm code To use HEX codes use...

Page 25: ...n event insert blanks by pressing the key in place of the two digits Examples P A alarm entered at RKP Fire alarm entered at RKP Engineer mode entered Bell fuse failure Auxiliary fuse failure Battery...

Page 26: ...tion requires all four Groups to be programmed Enter Group 1 Alarm Codes Now select where you require the Alarm Codes to be reported to No reporting for group Report to telephone number 1 backup to nu...

Page 27: ...ill work 11 21 Follow Select Enter This function is used in conjunction with Programmable Output 1 and 2 option 5 Follow Zone Enter the zone to be followed Enter for zones 1 to 8 or if no zone is to b...

Page 28: ...be emitted every 5 seconds when the panel is in day mode Press a function key to stop the error tone The fault will remain on until the fault has been corrected To determine the fault go into the log...

Page 29: ...00mA Strobe 500mA PR1 PR2 250mA Alarm bell time 2 to 20 minutes software programmable Zone type Normally closed loops which activate when opened or short circuit Zone loop current 0 76 to 1 03mA Zone...

Page 30: ...1 System option 2 System option 3 Spare Re Sets First telephone number Second telephone number Customer account code Downloading access code Zone alarming reporting codes Zone tamper reporting codes S...

Page 31: ...activation System Option 2 1 Default 24 hour test dial 2 Default no dial in 3 Default Standard filters 4 Default Audible P A System Option 3 1 Default User NVM reset 2 Default Open zones not displaye...

Page 32: ...Alarm Zone 5 Alarm Zone 6 Alarm Zone 7 Alarm Zone 8 Alarm Tamper Alarm Reporting Codes Zone 1 Tamper Zone 1 Tamper Zone 1 Tamper Zone 1 Tamper Zone 1 Tamper Zone 1 Tamper Zone 1 Tamper Zone 1 Tamper...

Page 33: ...User 5 Set User 6 Set User 7 Keyswitch User Unset Reporting Codes Unset User 1 Unset User 2 Unset User 3 Unset User 4 Unset User 5 Unset User 6 Unset User 7 Keyswitch Maintenance and Priority Codes P...

Page 34: ...storal Reporting Codes User code Restoral Bell Timeout Restoral Battery Restoral A C Restoral Test Transmission Digicom Codes Keyswitch Set Configuration Group Allocation Group 1 Group 2 Group 3 24hr...

Page 35: ...Rins171 Issue 6 Page 35...

Page 36: ...Page 36...

Reviews: