background image

 

 

 

 

 

6160EX Keypad  

 

User Instructions 

 

 

 
 
 
 
 
 
 
 
 
 

 
 
 
 

 

 
 
 

Summary of Contents for 6160EX

Page 1: ...6160EX Keypad User Instructions...

Page 2: ...Alarm 8 Viewing the event log 9 Omitting Zones From the System 10 Chime 11 Setting the Time and Date 11 Adding and Removing Keyfobs 12 Adding and Removing Keytags 12 Adding and Changing User Codes 13...

Page 3: ...user interface device that displays system conditions and allows user control Reset The action of clearing the alarm or fault condition and restoring the system to the steady state condition Tamper A...

Page 4: ...gned as the master user Each user can have a user code master user code is 1234 by default and either a fob or a tag Your installer will indicate which methods are available on your system The followi...

Page 5: ...e that the system has set and the screen will go Blank Note To abort the setting procedure during the exit time press the key To full set the system keyfob Press the ON button on the keyfob Full setti...

Page 6: ...ss the OFF button on the keyfob The system unsets with a double beep To unset the System keytag Hold card briefly in front of keypad LED s The system unsets with a double beep Note If no response is o...

Page 7: ...r installer can set up these detectors To Part set the system proceed exactly as for Full setting except instead of pressing 1 Full Press 2 PART to Part set OR Press 3 Night to Night set The keypad to...

Page 8: ...r an Alarm After an alarm has been cancelled and displayed it must be reset This is typically done by typing your User Code again The display will return to the Day Mode display If the alarm message r...

Page 9: ...backwards and forwards through the log as follows Key 1 Scroll Back one event Key 3 Scroll Forwards one event Key 4 Scroll Backwards 10 events Key 6 Scroll Forwards 10 events Pressing the Key at any...

Page 10: ...your User Code 2 Press 6 OMIT 3 Type the zone number to be omitted Each zone number is a double digit e g 03 or 14 The display will show the zone 4 Repeat step 3 for any other zone if needed 5 Press t...

Page 11: ...r 14 4 Repeat step 3 for any other zones 5 Press the key to finish The display will Show that the Chime function is activated To disable the Chime function 1 Type in your User Code 2 Press 9 CHIME 3 P...

Page 12: ...ard then release buttons 5 Press and release any single button on the fob A moment later a double beep is heard The fob is now added to the system Note If at any time a triple beep is heard the proced...

Page 13: ...Users can only change their own code To change or add a user code 1 Enter master user code or the user code to be deleted 2 Press 8 CODE 3 Press the user number that you want to program 1 to 8 4 Ente...

Page 14: ...Code 3 Press the user number 1 8 4 The current descriptor is now shown 5 To edit the descriptor the following buttons are used Key Output Delete the last character 1 1 dash full stop comma 2 A B C 2 a...

Page 15: ...bells switch off the system enters walk test mode to allow testing of the sensors 5 Activate each detector in turn As each detector is activated the keypads will beep twice and the zone number will be...

Page 16: ...d Lockout 5 wrong codes have been entered The keypads will lockout for 10 minutes Do not touch the keypad during this time as this extens the time RF Supervision The system has lost the signal from a...

Page 17: ...Hotkeys can be enabled or disabled by your installer The following Hotkey functions are available Function Button Combination Panic Alarm Assistance 1 Fire 3 Additional Information System Settings Ent...

Page 18: ...18 Zone Information Zone Location Full Part Night 1 2 3 4 5 6 7 8 9 10 11 12 IU1 1233 Rev 1 2...

Reviews: