CR123A x 1 

 

 

 

 

 

 

 

          

  

Version 2: Neues Verfahren zur Inbetriebnahme 

1 - BESCHREIBUNG 

 
Das Funkbedienteil EKZ017200C dient zur Steuerung der drahtlosen Zentrale 
DOMONIAL 800++ mit Hilfe eines Codes oder mittels Ident-Datenträgers  
(TAG). Seine Bedienung ist ohne Änderungen von Einstellungen an der  
Zentrale benutzerdefinierbar: 

 

 

Programmierung von Benutzer-Codes, 

 

Ident-Datenträgers Zuweisung für Benutzer, 

 

Einstellung der Komplettüberwachungsfunktion  

mit oder mit oder ohne Code. 

 
Über das EKZ017200C können die 3 Scharfschaltemöglichkeiten  
der Zentrale (Haupt/Gesamtbereich, Teiraum, Melde) unabhängig  
voneinander aktiviert, deaktivert und die optionalen Funkempfänger  
gesteuert werden. 

 

 - Digitale Tastatur zur Eingabe des PIN-Codes. 

 - Scharfschaltung Haupt/Gesamtbereich. 

 - Scharfschaltung Teilraumüberwachung  

 - Scharfschaltung Meldergruppe (gleichzeitiges Drücken) 

 - Ident-Datenträgers Empfangsbereich (Abstand ~2,5 cm) 

 - Alarmtaste (gleichzeitiges Drücken) 

 - LED-Anzeige 

 - Funkempfänger Ein 

 - Funkempfänger Aus 

 
 

2 - BETRIEB 

 

Benutzer     

Mit dem Bedienteil EKZ017200C können 10 Benutzer verwaltet werden. Für 
jeden Benutzer gibt es: 

-

 

1 vier- oder sechsstelligen PIN-Code 

-

 

1 Ident-Datenträger (TAG). 

 

 Der Hauptbenutzer (Nr. 1) verfügt standardmäßig über den PIN-Code 1234 

oder 001234 und kann alle Programmierfunktionen des Bedienteils nutzen 
(Codes und TAG), 

 

 für die anderen Benutzer existiert kein standardmäßig vergebener Code. 

 

Mit Hilfe eines Überfall-Codes (zusätzlich zum Code eingegebene Ziffer 1) kann 
der Befehl zur Unscharfschaltung der Zentrale gegebenen werden, wobei 
gleichzeitig signalisiert wird, dass es sich um eine Überfall handelt. 

 

Zur Eingabe des PIN-Codes dürfen die Tasten der Tastatur maximal 20 Mal 
gedrückt werden (30 Mal bei 6-stelligen Codes). Danach wird die Tastatur für 5 
Minuten blockiert (Falschcode) und eine entsprechende Meldung an die Zentrale 
übermittelt. 

 

Sabotageschutz 

Falls versucht wird, das Bedienteil zu öffnen oder abzureißen, wird eine Meldung 
an die Zentrale übermittelt und ein akustisches Signal ausgegeben. 
                                  

Signal = 2 Pieptöne > Version 2 

 

Kontrollanzeige 

Die Funktionsweise der LEDs und des Summers sind in der folgenden Tabelle 
dargestellt: 

 

 

Erkannter 

TAG  

Deaktivieren 

akzeptiert 

Aktivieren 

akzeptiert 

Unbekannter 

TAG  

 

>20 eingegebene Ziffern oder 

>3 unbekannte TAGs  

Grüne 

LED  

0,2 Sek. 

0,5 Sek. 

Rote 

LED  

- - 3 

Sek. 

(Aufblinken) 

0,5 Sek. 

5 Min. (Aufblinken) 

Zurücksetzen nach 20 s 

Summer 1 

Piepton 

(0,2 Sek.) 

1 Piepton 

(1 Sek.) 

Pieptonfolge 

(3 Sek.) 

1 Summton 

(0,5 Sek.) 

1 Summton (0,5 Sek.) 

 
 
 

          

 
 

                 

Version 2 : New arming procedure 

1 - PRESENTATION

 

 

The EKZ017200C radio keypad is designed to control the 
DOMONIAL 800++ wireless central unit using the code or the 
proximity fog (TAG). Its operation can be customized without action 
on the alarm central unit: 

 

 

programming of user codes, 

 

associating the TAG to the users 

 

definition of the total setting function, with or without 

code. 

 

 EKZ017200C can set the total, the partial or the annex zone. It 
can only unset all the zones. It can switch the optionnal wireless 
receivers too. 

 

 - Digital keypad used for entering secret code. 

 - Arming Total zone. 

 - Arming Partial zone  

 - Arming Annex zone (pressed simultaneously) 

 - TAG receiving area (approximatly 1 inch). 

 - Keypad panic button (pressed simultaneously). 

 - LED indicator 

 - Switch on the wireless receiver 

 - Switch off the wireless receiver. 

 

 

 

2 - OPERATING 

 

Users 

The  EKZ017200C keypad manages 10 users. For each one : 

-

 

1 four or six digits secret code 

-

 

1 TAG 

 
 

 the master user (n°1) has a factory default code (1234 or 001234) and can do 

full operation and programming of keypad (codes and TAG), 

 

 

 the other users haven’t got any factory attibuted code. 

 
 

A duress code (obtained by adding 1 to the last digit of your code), for 
transmitting a disarming command to the control panel while informing it that it 
concerns an aggression. 
 
The user’s code must be entered in a 20 digits sequence (30 in 6 digits code 
mode). Beyond, the keypad is locked (anti-fraud blocking) for 5 minutes and the 
information is sent to control panel. 

 

Keypad tamper 

In the event of an attempt to open the keypad or pull it away, a message is sent 
to the central unit and a sound is played. 
                                  

Sound = 2 beeps > Version 2 

 

Indicator light 

The LED indicators and the buzzer operate as the following table : 

 
 

 

Recognized 

TAG  

Unsetting 

accepted 

Setting 

accepted 

Unknown 

TAG  

 

Entered digits >20 or 

unknown TAG >3 

Green 

LED  

0,2s 0,5s  -  - 

Red 

LED  

- - 

3s 

(Flashing) 

0,5s 

5 mn (Flashing) 

Reset after 20s 

Buzzer 

1 high beep 

(0,2s) 

1 high beep 

(1s) 

Cadensed 

beeps (3s) 

1 low beep 

(0,5s) 

1 low beep (0,5s) 

 
 
 
 
 
 
 
 

 

Neu 

New 

V2 

So erkennen Sie die Version V2 auf dem CSK: 
-

 

Durch das Präsentieren des TAG für mehr als 1,5 s  
(keine Scharfschaltung mehr) 

-

 

Anhand der Kamine auf den Tasten zur Scharfschaltung 

-

 

Anhand der 2 Pieptöne beim Öffnen des CSK (nur 1 bei V1) 

How to recognize the version V2 on the CSK : 
-

 

By presenting the TAG more than 1,5s (no more arming) 

-

 

By chimey on the Arming keys 

-

 

By 2 beeps when opening the CSK (only one on V1) 

 

Montageanleitung / Installation instructions 

 

 

 

 

T

T

A

A

G

G

 

 

Summary of Contents for EKZ017200C

Page 1: ...lle dargestellt Erkannter TAG Deaktivieren akzeptiert Aktivieren akzeptiert Unbekannter TAG 20 eingegebene Ziffern oder 3 unbekannte TAGs Grüne LED 0 2 Sek 0 5 Sek Rote LED 3 Sek Aufblinken 0 5 Sek 5 Min Aufblinken Zurücksetzen nach 20 s Summer 1 Piepton 0 2 Sek 1 Piepton 1 Sek Pieptonfolge 3 Sek 1 Summton 0 5 Sek 1 Summton 0 5 Sek Version 2 New arming procedure 1 PRESENTATION The EKZ017200C radio...

Page 2: ... 4 Jahre 15 Nutzungen pro Tag 100 000 Befehle Sabotageschutz Öffnen und Abreißen Batteriefehler zwischen 2 5 V und 2 7V Abmessungen L H T 85 mm x 135 mm x 25 mm 30 mm x 47 mm x 3 5 mm Gewicht 130 g 2 g Betriebstemperaturbereich 0 C bis 40 C 0 C bis 40 C Lagertemperaturbereich 20 C bis 70 C 20 C bis 70 C Relative Feuchtigkeit 80 IP67 Funk Typ FM Schmalband ISO IEC 15693 2 Frequenzen 868 25 MHz 13 5...

Page 3: ...nd zeigen Sie Ihren TAG Die rote LED leuchtet für 3 Sekunden auf und eine Pieptonfolge ertönt Die Zentrale gibt ein akustisches Signal zur Bestätigung der Funktion aus Unscharfschalten des Haupt Gesamtbereichs Meldergruppe Halten Sie Ihren TAG etwa 1 cm vor den TAG Empfangsbereich Die grüne LED leuchtet für 0 5 Sekunden auf und ein durchgehender Piepton ertönt Die Zentrale gibt ein akustisches Sig...

Page 4: ... Sie die Lautstärke der akustischen Signale ein Auswahl der Sirene durch mehrmaliges Drücken Wählen Sie die Lautstärke 0 bis 7 0 Stumm Info Die ausgewählte Sirene gibt einen Piepton in der gewählten Lautstärke aus So wählen Sie den 4 oder 6 stelligen Modus aus 6 stelliger Code Halten Sie beim Einsetzen der Batterie 6 Tasten gedrückt Alle anderen Schritte wie beschrieben ausführen 4 stelliger Code ...

Reviews: