SECTION 5
5.18
DANGER
Before proceeding to dismantle filter, reduce pressure in supply conduit. While
dismounting the filter slide gate, hold the cover with the other hand. Stand away from filter
cover vertical direction.
Scope of maintenance activities
Reduce pressure in supply conduit.
Pressure in conduit can be reduced by pressing the head of the
pneumatic connection until resistance is felt.
Slide out securing slide lock (1) – figure (5.7).
Hold the filter cover (2) with the other hand. After removing slide lock,
the cover is pushed off by the spring located in the filter housing.
The insert and the filter body should be carefully washed with water and blown
through with compressed air. Assembly should be done in reverse order.
Cleaning the air filter (filters):
•
every 3 months of use,
5.3.4 DRAINING WATER FROM AIR TANK
Scope of maintenance activities
Open out drain valve (1) placed in lower part of tank (2) – the tank is placed on
brackets of right longitudinal frame of lower frame.
The compressed air in the tank causes the removal of water to the
exterior.
Summary of Contents for PT510
Page 2: ......
Page 6: ......
Page 7: ...SECTION 1 BASIC INFORMATION ...
Page 22: ...Pronar PT510 SECTION 1 1 16 ...
Page 23: ...SECTION 2 SAFETY ADVICE ...
Page 41: ...SECTION 2 Pronar PT510 2 19 FIGURE 2 3 Locations of information and warning decals ...
Page 42: ...Pronar PT510 SECTION 2 2 20 ...
Page 43: ...SECTION 3 DESIGN AND OPERATION ...
Page 64: ...Pronar PT510 SECTION 3 3 22 ...
Page 65: ...SECTION 4 CORRECT USE ...
Page 93: ...SECTION 5 MAINTENANCE ...
Page 120: ...Pronar PT510 SECTION 5 5 28 FIGURE 5 10 Trailer s lubrication points part 1 ...
Page 121: ...SECTION 5 Pronar PT510 5 29 FIGURE 5 11 Trailer s lubrication points part 2 ...
Page 131: ...NOTES ...
Page 132: ... ...