Pr
o
Minent
®
24
Annex
3FBEh
user pump location
0
number of entries
U8
8
ro
1
location
string[4]
location character 29 - 32
ro
2
location
string[4]
location character 25 - 28
ro
3
location
string[4]
location character 21 - 24
ro
4
location
string[4]
location character 17 - 20
ro
5
location
string[4]
location character 13 - 16
ro
6
location
string[4]
location character 9 - 12
ro
7
location
string[4]
location character 5 - 8
ro
8
location
string[4]
location character 1 - 4
ro
6509
0
Al1_action=1 warn,=3 err
U8
Level min error
ro
6519
0
Al2_action
U8
Level min warning
ro
6529
0
Al3_action
U8
Batch error
ro
6539
0
Al4_action
U8
Cal warning
ro
6549
0
Al5_action
U8
Sys error
ro
6559
0
Al6_action
U8
Bus off
ro
6569
0
Al7_action
U8
add2
ro
6579
0
Al8_action
U8
add3
ro
6600
0
Al_state0_7
U8
0=no error, 1=error
B
Explanations on the objects
DeviceState [Index 0x2A10, Subindex 0x00]
The object ‚DeviceState’ includes the present operating status and the existing errors of the
pump. ‚DeviceState’ can only be read.
Bit location
Meaning
15 (MSB)
Manual / bus operation
14
Pause
13
internal error
12
internal error
11
Operating mode:
1
continuous
10
2
batch operation
9
3
external contact
8
4
analogue input
7
Stop
6
internal error
5
Warning (e.g. tank fill level)
4
Suctioning active
3
Lowering (only in ProMinent systems)
2
Calibration invalid
1
Tank metering
0 (LSB)
no remote operation possible
Table 1: DeviceState bit values