Troubleshooting
Flash code CANopen LED, bottom
Colour
Flash code
Cause
Remedy
red
illuminated
Controller is BUSOFF
Contact customer service
red
flashing*
RPDO error
Contact customer service
red
double
Error status ERROR-
Contact customer service
flashing***
WARNING
red
triple
Error status ERROR-
Contact customer service
flashing
WARNING
green
illuminated
Bus status OPERATIONAL
- (standard operation bus)
green
flashing*
Bus status PRE-OPERATIONAL
wait briefly or start pump
via bus
green
simple
Bus status STARTUP
wait briefly or set pump
flashing**
active for bus operation
(see Chap. 7, “Settings”)
green
pulsating
Bus status INIT
wait briefly
*
**
***
Ignore the flash codes for approx. 2min. (acknowledge alarm, if any) after connecting the metering
pump.
Table: Flash codes CANopen LED
NOTE
For “error messages through CANopen telegramme” see end of the annex!