Pr
o
Minent
®
35
Annexe
Annexe
A
Répertoire d’objets de la pompe doseuse
Default mapping
Index
S
Nom
Type
Description
Défaut
1000h
0
device type
U32
CiA DSP 404
00400194h
ro
1001h
0
Error register
U8
9.6.3 in 301
ro
1008h
0
manufacture device name
string
Device abbreviation [4]
“GDLT“
ro
1009h
0
manufacture hardware version
string
Hardware version [4]
“0000“
ro
100Ah
0
manufacture software version
string
Software version [4]
“0000“
ro
1010h
store parameters
array
0
number of entries
U8
95
ro
1
save all parameters
U32
rw
2
save comm.. parameters
U32
rw
3
save process.. parameters
U32
rw
4..95
reserved
U32
rw
1011h
restore parameters
array
0
number of entries
U8
3
1
load(restoredefault) parameters
U32
rw
2
load comm.. parameters
U32
rw
3
load process.. parameters
U32
rw
1017h
0
producer heartbeat time
U16
50-2000 [ms]
730
rw
1018h
identity object
number of entries
U8
4
ro
VendorID
U32
0xE1
ro
ProductCode
U32
0x00605503
ro
RevisionNumber
U32
0x00000001
ro
SerialNumber
U32
dynamic
ro
2A00h
0
set frequency
U16
set frequency
[0.1% of stroke max]
RPDO1
wo
2A01h
0
actual frequency
U16
actual frequency
[0.1% of stroke max]
TPDO1
ro
2A02h
0
batch time stamp value
U16
Time stamp last
received command
RPDO2
wo
2A03h
0
batch value
U16
Volume last received
command in strokes
RPDO2
wo
2A04h
0
stroke length
U8
stroke length
TPDO1
wr
2A05h
0
niveau
U8
liquid niveau
TPDO2
ro
2A06h
0
actual frequency 2
U16
actual frequency
[0.1 strokes/min]
TPDO2
ro
2A10h
0
device state
U16
Tabelle 1 DeviceState
BitValues
TPDO1
ro
2A11h
0
device control
U8
Tabelle 2 DeviceControl
BitValues
rw
2A12h
0
device mode
U8
Tabelle 3 DeviceMode
BitValues
wo
2A20h
0
stroke max
U16
max. stroke value
(strokes/min)
ro
2A21h
0
metering value
float
[
µ
l/stroke]
(at 100% strokelength)
wr
2A22h
0
measuring unit
U8
0=Litre, 1=Gallon
wr