Pr
o
Minent
®
50
Anexo
3FBEh
user pump location
0
number of entries
U8
8
ro
1
location
string[4]
location character 29 - 32
ro
2
location
string[4]
location character 25 - 28
ro
3
location
string[4]
location character 21 - 24
ro
4
location
string[4]
location character 17 - 20
ro
5
location
string[4]
location character 13 - 16
ro
6
location
string[4]
location character 9 - 12
ro
7
location
string[4]
location character 5 - 8
ro
8
location
string[4]
location character 1 - 4
ro
6509
0
Al1_action=1 warn,=3 err
U8
Level min error
ro
6519
0
Al2_action
U8
Level min warning
ro
6529
0
Al3_action
U8
Batch error
ro
6539
0
Al4_action
U8
Cal warning
ro
6549
0
Al5_action
U8
Sys error
ro
6559
0
Al6_action
U8
Bus off
ro
6569
0
Al7_action
U8
add2
ro
6579
0
Al8_action
U8
add3
ro
6600
0
Al_state0_7
U8
0=no error, 1=error
B
Explicación de los objetos
DeviceState [Index 0x2A10, Subindex 0x00]
El objeto ‚DeviceState’ contiene estados de funcionamiento actuales y fallos pendientes de la
bomba. El ‚DeviceState’ sólo se puede leer.
Bits
Significado
15 (MSB)
Funcionamiento manual / de Bus
14
Pausa
13
Fallo interno
12
Fallo interno
11
Modo de funcionamiento: 1
continuo
10
2
Funcionamiento batch
9
3
Contacto externo
8
4
Entrada analógica
7
Parada
6
Fallo interno
5
Advertencia (p.ej., estado de llenado del recipiente)
4
Aspiración activada
3
Contrataladro (sólo en instalaciones de ProMinent)
2
La calibración no es válida
1
Depósito de dosificación
0 (LSB)
Teleoperación imposible
Tabla: 1 DeviceState BitValues
Summary of Contents for delta
Page 55: ...ProMinent 55...
Page 56: ...ProMinent 56...
Page 110: ...ProMinent 55...
Page 111: ...ProMinent 56...