Operating Instructions
Warning Device SH 2500 uni-b, (audible, battery-operated)
BA 30.12.01.00076
Last updated May 2010 / Index 00
Page 1/3
(42500190)
1.
Safety
Instructions for installation, maintenance and operating staff
This unit should only be installed and maintained by qualified specialist personnel.
All persons commissioned with the task of setting up, starting up, operating, maintaining and repairing the device
at the company of the user must have read and understood the operating instructions, in particular the “Safety”
section.
The company of the user must take internal measures to ensure that:
The users of the device are trained.
They have read and understood the operating instructions.
The operating instructions are accessible to them at all times.
The responsibilities for the various tasks to be carried out on the unit must be clearly specified and adhered to.
Do not cover the opening for the alarm generator sound.
Do not close the reference pressure hole.
Installation location requirements
The unit may not be operated in rooms where there is a risk of explosion.
The ambient temperature may not exceed 50 °C.
Intended use
The unit is designed to monitor the operating vacuum.
For safety reasons, the unit may not be modified or changed without approval.
The operating, maintenance and servicing conditions prescribed in these operating instructions must be
observed.
Rectify any faults before starting up the device. Should faults occur during operation, they must be rectified
immediately.
2.
Technical Specifications
Power supply
2 x D batteries 1.5 V, 18,000 mAh
Frequency range of alarm generator
Approx. 3,000 Hz
Noise level of alarm generator
> 95 dB(A)
Dimensions 120x80x70
mm
3.
Description
The warning device is designed for lifting units that require a self-powered warning device.
The warning device creates an audible warning signal as soon as the vacuum falls below approx. 600 mbar.
It also monitors vacuum drops and increases.
No warning signal occurs when the vacuum drops very quickly (lowering the workpiece) or increases very quickly
(picking up dense work pieces with a small suction plate). Nor does a warning signal occur if the vacuum is lower
than approx. 70 mbar.