AFV-P Series High Performance Programmable AC Power Supply
46
3.5.2.5
Output Voltage Range
At the TESTING subpage 3 (BASIC mode), users are allowed to set the output voltage
range with options from 0V to 310V by using the touch screen and the rotary knob
(refer to Subsection 3.2). When users set value of the output voltage exceeding the
preset range (that is, the preset value of the maximum to minimum output voltage),
the product can automatically adjust the set value to meet the preset range.
3.5.2.6
Output Frequency Range
At the TESTING subpage 4 (BASIC mode), users are allowed to set the output fre-
quency with two options: A version 40Hz-500Hz or B version 15Hz to 1000Hz, by us-
ing the touch screen and the rotary knob (refer to Subsection 3.2). When users set
value of the output frequency exceeding the preset range (that is, the preset value of
maximum to minimum output frequency), the product can automatically adjust the
set value to meet the preset range.
3.5.2.7
Synchronized Signal
At the TESTING subpage 4 (BASIC mode), users are allowed to enable the synchro-
nized signal with three options of EVENT, OFF and ON, and the default option is
EVENT. EVENT indicates that the product outputs a 5V DC pulse signal when the
product output changes; OFF indicates that the synchronized signal is disabled; ON
indicates that the product continuously outputs a 5V DC signal when the product
output is on, and stop the 5V DC signal when the product output is off.
Figure 3.32 Three options of the synchronized signal (BASIC mode)