Model PD6262 Analog Dual-Input Rate/Totalizer Instruction Manual
29
Display Functions & Messages
The following table shows the main menu functions and messages in
the order they appear in the menu.
Display Parameter
Action/Setting
Description
setup
Setup
Enter
Setup
menu
Input
Input
Enter
Input
selection menu
Ch-A
*
Input
Set input type for channel A (*or B)
mA
4-20 mA
Set meter for 4-20 mA input
volt
0-10 VDC
Set meter for
10 VDC input
total
Total
Enable/disable totalizer functions
YES
Yes
Enable totalizer functions
No
No
Disable totalizer functions
units
Unit
Select the display units/tags
Ch-A
*
Rate unit
Set rate unit or tag for channel A (*or B)
Ch-C
Math unit
Set unit or tag for math channel C
Tot-A
*
Total unit
Set total unit or tag for channel A (*or B)
Gtot-A
*
Grand total unit
Set grand total unit or tag for channel A
(*or B)
Dec pt
Decimal point
Set decimal point
Ch-A
*
Decimal point
Set decimal point for channel A (*or B or C)
Rate
*
Rate
Set rate decimal point (*channel A and B
only)
Total
*
Total
Set total decimal point (*channel A and B
only)
Gtotal
*
Grand total
Set grand total decimal point (*channel A
and B only)
prog
Program
Enter the
Program
menu
InCAL
Input
calibration
Enter the
Input Calibration
menu
SCAL A
Scale A
Enter the
Scale
menu for channel A
SCAl B
Scale B
Enter the
Scale
menu for channel B