Faults
59
Symptom
Potential cause
Remedy
Triggers without driving
a fastener (blank shot).
The pusher spring is
defective.
Inform customer service
(see page
Fehler!
Textmarke nicht
definiert.
).
The magazine is dirty.
Clean the magazine.
Incorrect fasteners
loaded in the
magazine.
Empty the magazine.
Fill the magazine with
PREBENA fasteners
(starting on page 26).
The tacker is not being
sufficiently lubricated.
Add PREBENA special
driver oil to the
compressed air
connection in use.
Trigger several times.
Operating pressure is
too low.
Increase operating
pressure (see page 32).
The piston with the
driver does not return
to the initial position
after the driving
process.
Inform customer service
(see page
Fehler!
Textmarke nicht
definiert.
).
The triggering process
is not completed.
Inform customer service
(see page
Fehler!
Textmarke nicht
definiert.
).
The driver is bent.
Inform customer service
(see page
Fehler!
Textmarke nicht
definiert.
).
Summary of Contents for 1A-AZ16BNH
Page 28: ...Eintreibger t bedienen 4C WZ38BNH 4C WZ38BNH400 28...
Page 47: ...Nach dem Betrieb 47 Schlie en Sie das Magazin siehe Seite 29...
Page 117: ...After operation 47 Close the magazine see page 28...