2.2. Set-up
The following is a list of steps describing the required actions to get the power supply
set up.
1. Check for any visual damage that could have happened during shipment. Check all
plug-in connectors on PCBs.
WARNING: Make sure that the
power is locked out before
connecting the input power.
2. Ensure that both the circuit breakers, located on the door of the unit, are in the OFF
position. Wire the power supply to the supply voltage as described in section
3. Connect the heating coil and load to the output of the unit (see section
4.).
4. Connect and test the cooling water supply, as described in section
5. Read section
0to become familiar with the front panel controls.
6. Do initial setups of the internal heat station, as described in section 6.1.
7. Do the tuning of the heat station, as described in section
6.2 The power supply will
not operate if the emergency stop button is pressed in or the door is not closed.
8. The unit is now ready for operation, and can be controlled by the front panel.
9. The unit is programmed for power control. For inverter current, load voltage or
auxiliary control see section 5.1.
7