M-CV: Output voltage monitoring signal (0~5V, 100%=5V).
GND; Common terminal for monitoring signals (ground).
7.2. Terminals for external connect (CN-1)
7.2.1. Input contacts(TB2)
HEAT; Connecting terminal HEAT and terminal COM will start the unit in the
external heat control mode.
E-STOP: Opening a connection between terminal STOP and terminal COMM
will stop the heat cycle if the external e-stop is enabled in the program. This will
activate the UVR trip. The front panel E-STOP switch remains in circuit.
COM; Common terminal for input contacts.
INT: A user defined trip can be wired between terminals AUX-IN and COM if the
auxiliary interlock is enabled in the program.
RESET: Connecting terminal RESET and terminal COM will issue a fault reset if
the external reset is enabled in the program.
COM; Common terminal for input contacts.
7.2.2. Relay output contacts (TB3)
HEAT; Closes while power supply is in heating cycle.
FAULT; Closes when power supply is in a fault or tripped condition.
READY; Closes while power supply is in stand-by.
RELAY
LAMP
LAMP, RELAY OUTPUT
RELAY
LAMP
LAMP, RELAY OUTPUT
TB5
TB3
7.2.3. Relay output contacts (TB3)
HEAT; Closes while power supply is in heating cycle.
FAULT; Closes when power supply is in a fault or tripped condition.
READY; Closes while power supply is in stand-by.
POWER; User supplied lamp power 10-240V AC or DC
7.2.4. RS-485 port (TB6)
COMM-A; Positive signal of RS-485.
COMM-B: Negative signal of RS-485.
COMM-C: Ground of RS-485 connection.