3. Press “ESC” key to return to PROGRAM menu without setting change.
5.1.4. Job order
Setting job parameters to operate the power supply in “PROGRAMMED” mode. The
power supply can be programmed for 15 separate heating profiles or jobs. Each profile
can contain up to 29 steps.
1. Select “JOB ORDER” in the PROGRAM menu.
2. Enter a job number (1~15) with numeric keys and press “ENT” key to select the
job profile. If a heating profile has previously been entered in a Job, then the
values will be displayed.
3. Enter value for each item and press “ENT” key to change and move the cursor to
the next item.
4. Use UP (▲) and DOWN (▼) key to move the cursor only without changing value.
5. Press “SAVE” key to save all the changed values and return to “JOB ORDER”
menu.
6. Press “ESC” key to return to “JOB ORDER” menu without saving changes.
REPEAT:
Setting numbers of auto repeat (1~100 times)
Each Job has an auto repeat function, which enables a selected job to be
repeated up to 100 times. (If 0 set, proceed as 1).
PAUSE:
Pausing time must set when auto repeat times is over 1.
(Input range=0.1~6399sec. but must set 1sec. or more).
STEP 1~29:
Enter the values of power level & time for each step.
POWER: (0~100 %,). The power level will ramp from the last power level to
the power level requested.
TIME: (0.1~6399sec).
Note: Enter “0” for the values of power level & time both at a step to stop the job
process. Other steps after this step shall be ignored even they contained any values.
5.1.5. System parameters
Setting system functions
1. Select “SYSTEM” in the PROGRAM menu.
2. Enter values or select menu with numeric keys or LEFT (◄) and RIGHT (►) key
and press “ENT” key to change values and move cursor to next item.
3. Press “SAVE” key to save all the changed values and return to PROGRAM menu
4. Press “ESC” key to return to PROGRAM menu without setting change.
POWER LIMIT:
Set the percentage of output power to limit level (0~100%).
100% of POWER LIMIT is 25kW, If 50% is set power output shall be limited to 12.5kW.
CAP.V LIMIT:
Set the percentage of capacitor voltage to limit level (0~100%).
100% of capacitor voltage is 500V
INV.C LIMIT:
Set the percentage of inverter current to limit level (0~100%).
100% of inverter current is 300A.
SHDN W/TEMP:
Set the temperature of inlet water to shutdown power supply as
centigrade (0~40
℃
). If the water temperature increase over this value, then the power
supply gets a fault state and stops heating
17