1.5. Internal heat station
Resonant capacitors
Mounting space provided for sixteen
capacitors. Eight 210nF, 500V or 8
200nF, 700V capacitors supplied.
330nf available
Series Parallel Capacitor Rail
Kit available (optional)
Series inductor
Adjustable for load matching
1.6. Protection
Power
Limited to 12.5kW in any feedback
configuration
Inverter output current
Limited to 250A peak. Short circuit
protected.
Resonant capacitor voltage
Limited to 500V rms
Line current
50A Circuit breaker
DC link current
80A Semiconductor fuse
Temperature and cooling water
Temperature switch on inlet water.
Differential pressure switch between
water inlet and outlet.
Safety Interlocks
Emergency stop button or door switch
opens the main circuit breaker.
1.7. Load
Quality factor of load
Will operate with any load Q (including
resistive loads), provided that the
output frequency and voltage is within
the specifications.
Connection
Selectable between left and right.
Custom output connection provided.
1.8. Cooling water
Maximum pressure
100PSI
(690kPa)
Minimum differential pressure
30PSI
(207kPa)
Minimum water flow
2GPM (0.126l/s)
Maximum inlet water temperature
110
F
(43.3
C)
Minimum inlet water temperature
Approx. 90º F (32ºC)**
Minimum water resistivity
590
.in
(1500
.cm)
Supply hose location
Selectable between left or right
** must be set above dew point (see page 29)
5