HS TEMP:
HS TEMP must be set to 50
℃
always.
REST W/TEMP:
Set the restart-able inlet water temperature as centigrade (0~ SHDN
W/TEMP). Power supply can restart after water temperature has gone down to this
setting value. This value must be lower then SHDN W/TEMP value (37
℃).
COMM ADDR:
When the RS485 port is being used to control or monitor the power
supply, a unique ID for the machine can be entered (1~255).
BAUD RATE:
The communications baud rate for an RS485 connection can be set here
(4.8, 9.6, 19.2, 38.4 kbps).
FREQ:
Set operating frequency range. (Must be “135-400”) power supply can’t work
properly or can cause damage with the wrong value set.
C.RAIL:
Setting configuration of capacitor rail.
Set “PARL” for parallel configuration and “SER/PARL” for series-parallel configuration.
In case of this setting is C.RAIL = SER/PARL, capacitor voltage limit should be higher
by 2 times; the display on LCD will be twice.
5.1.6. Start frequency
Setting start frequency (135~440 kHz).
1. Select “START FREQ” in the PROGRAM menu.
2. Enter frequency of start and press “ENT” key to save the start frequency and
return to PROGRAM menu.
3. Press “ESC” key to return to PROGRAM menu without setting change.
5.1.7. Pass word
Changing password (0000~9999), Default Password is”0000”
1. Select “PASSWORD” in the PROGRAM menu.
2. Enter 4 digit password and press “ENT” key to save change and return to PROG
RAM menu.
3. Press “ESC” key to return to PROGRAM menu without setting change.
5.2. Status monitoring
5.2.1. Entering a monitoring
1. Turn on the power supply.
2. Pressing the FUNC button for a second until “FUNCTION menu” sign displays
on the LCD display window.
3. Select an item to monitor, use UP (▲) and DOWN (▼) keys and press “ENT” or
“SEL” key to display.
4. Press “ESC” key to exit the monitoring mode.
5.2.2. Parameter status
Show status of each parameters setting “OK” or “FAIL”
SYS: Display system parameter setting.
CONT: Display control parameter setting.
JOB: Display job parameter setting. If there is a “FAIL” parameter, power supply
will not start heating in PROGRAMMED mode.
18