4.1.2. Heat ON/OFF indicators.
These LEDs show whether the power supply is generating output or is off. (identified
by
--
in Figure 3.).
4.1.3. Program status indicator.
Identified by
--
in Figure 3. This read-out displays the programs status when using
the PROGRAMMED mode. Selected JOB profile number and STEP order will display
as like “1-12”
4.1.4. Time display indicator.
Identified by
--
in Figure 3. This read-out displays elapsed heating time as seconds
4.1.5. Power display indicator
Identified by
--
in Figure 3. This read-out displays the power output when the power
supply is operating.
4.1.6. LCD display
Identified by
--
in Figure 3. Details information display on LCD display.
MANUAL [T=2.5S] LOC
>> POWER LIMIT
P.S=50% C.V=500V
I.C=320A FRQ=370KHz
Figure 4: LCD display layout.
1st line:
Displays Control mode.
MANUAL [CONT]:
Indicates power supply working in manual continuous mode.
MANUAL [T=0.0S]:
Indicates power supply working in manual timed mode.
PROGRAMMED:
Indicates power supply working in programmed mode.
Selected job number display on Program status indicator.
LOC:
Indicates Local control mode.
EXT:
Indicates External control mode.
REM:
Indicates Remote control mode.
2nd line:
Alert status like fault, trip or limit. (See 4.1.1.)
3rd line:
Indicates requested power level (manual mode) or number of heat cycles in
auto repeat (programmed mode) and capacitor voltage.
P.S: Percentage of requested power level.
REP: Number of cycles in auto repeat.
Operating frequency
4th line:
Indicate capacitor voltage C.V: and
inverter current I.C.
12