Aux. interlock control
Power control mode
Feedback control mode
2) Job select:
Selecting job to proceed under Programmed mode.
3) Job order:
Setting Job parameters in each profile.
4) System parameters:
Setting control parameters.
Power limit
Capacitor voltage limit
Inverter current limit
Shutdown water inlet temperature (Does not apply for 25kW)
Restart water inlet temperature (Does not apply for 25kW)
Communication address
Communication baud rate
Operating frequency range
Capacitor rail configuration
5) Start frequency:
Setting start frequency.
6) Pass word:
Changing password.
5.1.1. Entering a program
1. Turn on the power supply.
2. Enter the program mode by pressing the “PROG” button for 1 second, to display
“password=” on LCD, enter password, and press “ENT” key to display
“PROGRAM menu”. (Default password=0000)
3. Use UP (▲) and DOWN (▼) key to move object item to program and select the
item with ‘ENT” or “SEL” key to enter into the item.
4. Press “ESC” key to exit program mode
5.1.2. Control mode
1. Select the item “CONTROL MODE” in PROGRAM menu.
2. Use UP (▲) and DOWN (▼) key to move object item to program and select the
item.
3. Select each value with LEFT (◄) and RIGHT (►) key and press “SAVE” key to
save the new values and return to PROGRAM menu.
4. Press “ESC” key, to return to PROGRAM menu without saving the changed
values
OPER MODE:
Setting operating mode.
MANUAL: Operate heat on/off or power level by switches or knob on the panel
or external signal.
PROGRAMMED: Operate process by programmed job profile.
HEAT CONT:
Setting Heat control mode.
LOCAL: Heating on or off by START/STOP switch on the panel.
EXT: Heating on or off by external heat contact input connected to E- HEAT
terminal of TB2 on EXT-TERM board.
REMOTE: Operate by control command from remote loader or PC.
15