4. REPAIR AND MAINTENANCE
1. Cleaning solenoid valve, cycle: every 3 months.
2. Cleaning Y filter, cycle: every 1 month.
3. Cleaning heater / cooler every 6 months.
4. Check the level switch, cycle: every 3 months.
In order to use the machine safely, please pay attention to the following items during
maintenance:
1
)
There should be at least 2 persons for checking machine. Please decrease the
temp., cutting power supply, drainage oil and water first.
2
)
Please ensure the machine stops working before maintenance and check because
high temp and then wearing the glove also.
3
)
In order to extend the system life and avoid of accident, please check and maintain
regularly.
4
)
Please ensure the temp is decreased to lower than 50
℃
before maintenance and check.
(Please note that open the machine is dangerous as machine is running!)
4.1 OPEN THE MACHINE
1)
Open the top cover (as shown in the picture, lift the cover slightly first and
then remove the top cover with force).
2)
Open the side cover, screw out the two fixing screws at the lower part of the
body side, and then lift up to open the side cover.
3
1
4
2
22