(2) Blow off: when blow on, press
and then blow off.
(3) Blow off: if customer doesn’t press
when blow on, blow situation will be closed automatically
as reaching setting time. (Time setting - parameters3: [F-16]).
8. Mute ON/OFF
(1) During alarm, press
and then mute on and alarm is mute.
(2) When mute on, press
and then mute off and hearing alarm.
9. Temperature monitoring
defaults the temp. CH1. If customer would like to check CH2 and CH3, please
press
when customer doesn’t operate any functions and then it will display temp. CH2. If
customer presses
, it will display temp. CH3. If customer would like to check the temp of
control box, please press
+
, it will show the temp.
3.8 TEMPERATURE SETTING AND AUTO-TUNNING
1. During running,
shows the current temp.
2. Press
,
shows 4 digits and right digit is flashing.
3. Press
or
to set the flashing value.
4. Press
to choose the digit from left to right.
5. Press
or
to increase or decrease the value.
6. Press
to save the setting and then 4 digits would stop flashing.
7. If customer doesn’t press any button once entering the setting mode, the setting mode
would be dropped out after 30 sec. and save the setting. (The revised value isn’t kept when
revising internal parameters.
8. Press
and
at the same time,
shows [AT] for auto-turning. Then, machine
will do PID calibration parameter. If the current temp.is flashing alternately, it means
under PID calibration parameter. Please note:
12