3.10 BASIC FUNCTION
1. During running,
show the current temp.
2. Press
+
2 sec at the same time, enter parameters 2 and show [F01.1].
3. Press
+
2 sec at the same time again, enter parameters 3 and
shows
[F01.2].
4. Press
or
to increase or decrease
the value.
5. Then, press
,
shows [F01.3]…[F-26]…[F01.2]by cycle for setting.
6. After completing, press
a while for exiting the setting mode.
7. Parameters 3: [Basic Parameter]
Code
Name
Explanation
Value
Unit
Factory
setting
Range
F01.2
Upper limit of CH2
temp.(Inlet)
Actual temp. > Setting temp. + Temp. upper
limit, PV>SV+[F01.2]alarm and shows [E-08]-
[CH2]
15
0-250
℃
/
℉
F01.3
Upper limit of CH3
temp. (Molding)
Actual temp. > Setting temp. + Temp. upper
limit, PV>SV+[F01.3]alarm and shows [E-08]-
[CH3]
15
0-250
℃
/
℉
F02.2
Lowest limit of CH2
temp. (Inlet)
Actual temp. > Setting temp. – Temp. lowest
limit, PV<SV-[F02.2]alarm and shows [E-07]-
[CH2]
15
0-250
℃
/
℉
F02.3
Lowest limit of CH3
temp. (Molding)
Actual temp. > Setting temp. – Temp. lowest
limit, PV<SV-[F02.3]alarm and shows [E-07]-
[CH3]
15
0-250
℃
/
℉
F03
Exhaust
After pump on, heater is delay on. Then, it
exhausts.
40
0
~
999
sec
F04
Heater delay
After pump on, please let heart delay on for
exhausting.
60
0-9999
sec
F05
Pump switch off
delay
After pressing ”Power” or “Pump”, pump will
stop working until reaching time or temp.
45
0-9999
℃
/
℉
/
sec
F06
Pump switch off
delay method
When pump switches off, customer can
choose to reach time or reach temp. for pump
delay switch off.
1
0: Stop as
reaching time
1: Stop as
reaching temp.
F07
Upper limit of
machine temp.
Upper limit of machine temp.
(
The parameter
of FOH series is 310.
)
150
0-350
32-662
℃
/
℉