e-mail: [email protected]
W
6385 MONTESSOURI STREET
LAS VEGAS, NEVADA 89113-1186
TOLL FREE: 800-258-8877
Order Fax: 800-223-8305
PPE
3) Open the electric control box (as shown in the picture below, open the electric
control box door with the key)
4.2 Y TYPE FILTER
1) Please use the good quality clean water. The unit is equipped the Y filter in the water
inlet to avoid the impurities get into the pipes.
2) When the impurities flow into the machine, it may cause the malfunction of the machine or
the decrease of the temperature control ability. Therefore, the Y-type filter must be
cleaned regularly.
3) Clean procedure: Switch off the power and water supply valve, open the Y filter cover to
clean.
4.3 SOLENOID VALVE
Replacement steps:
1
)
Open the top cover and the side cover. (Please see 4.1)
2
)
Remove the solenoid valve or replace it (as shown below).
23