Chapter 5 Function parameter
70
Ch
ap
ter 5
F1.16 Minimum input for AIC2
0.00V
~
F1.18
0.00V
☆
F1.17 F1.16 Corresponding to the set
-100.0%
~
100.0%
0.0%
☆
F1.18 AIC2 max. input
F1.16
~
+10.00V
10.00V
☆
F1.19 F1.18 Corresponding to the set
-100.0%
~
100.0%
100.0%
☆
For the function and use of curve 2, please refer to the description of curve 1.
F1.20 Minimum input for AIC3
0.00V
~
F1.22
-10.00V
☆
F1.21 F1.20 Corresponding to the set
-100.0%
~
100.0%
-100.0%
☆
F1.22 AIC3 Maximum input
F1.20
~
+10.00V
10.00V
☆
F1.23 F1.22 Corresponding to the set
-100.0%
~
100.0%
100.0%
☆
For the function and use of curve 3, please refer to the description of curve 1.
F1.24
AI
curve
selecti
on
Units digit
AI1 curve selection
321
☆
Curve 1(2 points
,
refere to F1.12~F1.15)
1
Curve 2(2 points
,
refere to F1.16~F1.19)
2
Curve 3(2 points
,
refere to F1.20~F1.23)
3
Tens
digit
AI2 curve selection (1-3, the same as the units
digit)
Hundre
ds digit
Panel encoder curve selection (1-3, the same as the
units digit)
Units digit, tens digit and hundreds digit of the function code are used to respectively select
the corresponding set curves of analog input AI1, AI2, Panel potentiometer
3 analog input can respectively select any one of 3 curves.
Curve 1, curve 2 and curve 3 are 2-point curve, they are set in F1 function code.
F1.25
AI
input
settin
g
selecti
on
Units digit
AI1 Below the minimum input setting selection
000
☆
Corresponding to the minimum input set
0
0.0%
1
Tens digit
Setting selection for AI2 less than minimum
input(0 to 1, ditto)
Hundreds
digit
Setting selection for panel potentiometer less than
minimum input(0 to 1, ditto)
The function code is used to set analog quantity and its corresponding setting when the
analog input voltage is less than the set Minimum Input.
Units digit, tens digit and hundreds digit the function code respectively correspond to the
analog input AI1, AI2, panel potentiometer. If 0 is selected, when the analog input is less than the
Minimum Input, the setting corresponding to the analog amount is the setting of minimum input of
the function code curve (F1.13, F1.17, F1.21).
If 1 is selected, when the analog input is less than the minimum input, the setting
corresponding to the analog amount is 0.0%.
F1.26
HDI Minimum input
0.00kHz
~
F1.28
0.00kHz
☆
F1.27
F1.26 Corresponding to the set
-100.0%
~
100.0%
0.0%
☆
F1.28
HDI Maximum input
F1.26
~
100.00kHz
50.00kHz
☆
F1.29
F1.28 Corresponding to the set
-100.0%
~
100.0%
100.0%
☆
This group function code is used to set the relationship between DI5 pulse frequency and its
corresponding setting.