Chapter 5 Function parameter
55
Ch
ap
ter 5
d0.00
Running frequency (Hz)
0.01Hz
Actual output frequency
d0.01
Set frequency (Hz)
0.01Hz
Actual set frequency
d0.02
Bus voltage (V)
0.1V
Detected value for DC bus voltage
d0.03
Output voltage (V)
1V
Actual output voltage
d0.04
Output current (A)
0.01A
Effective value for Actual motor current
d0.05
Output power (kW)
0.1kW
Calculated value for motor output power
d0.06
Output torque (%)
0.1%
Motor output torque percentage
d0.07
DI input status
-
DI input status, this value is a hexadecimal digits. The table listed each input terminal status
sequence for each bit:
0 to 10 bits
Input terminal status
0
Invalid
1
Valid
9 8 7 6 5 4 3 2 1 0
2
9
8
7
6
5
4
3
2
1
0
Reserved
DI8
DI7
DI1
DI2
DI3
DI4
DI5
DI6
2
2
2
2
2
2
2
2
2
Reserved
Figure5-1:
DI1 the sequence of the input terminal
d0.08
DO output status
-
DO output status, this value is a hexadecimal digits. The table listed each output terminal
status sequence for each bit:
0 to 10 bits
Output terminal status
0
Invalid
1
Valid
4 3 2 1 0
2
4
3
2
1
0
SPB
Relay 1
The manufacturer reserves the undefined
SPA
Relay 12
2 2
2 2
Figure5-2:
DO the sequence of the Output terminal
d0.09
AI1 voltage (V)
0.01V
AI1 input voltage value