38
Ch
ap
ter 5
display parameters 2
188
F6.03 Stop status display
parameters
0x0000 to 0xFFFF
0033
☆
189
F6.04
Load speed display
coefficient
0.0001 to 6.5000
3.0000
☆
190
F6.05
Decimal places for
load speed display
0:0 decimal places
2:2 decimal places
1:1 decimal places
3:3 decimal places
1
☆
191
F6.06
Inverter module radiator
temperature
0.0
℃
to 100.0
℃
-
●
192
F6.07 Total run time
0h to 65535h
-
●
193
F6.08 Total power-on time
0h to 65535h
-
●
194
F6.09
Total power
consumption
0 to 65535 kwh
-
●
195
F6.10 Product series number Frequency inverter series number
-
●
196
F6.11
Software version
number
Control board software version
-
●
197
F6.16 Monitor selection 2
1Kbit/100bit
10bit/1bit
d0.04
☆
parameter
number
parameter series number
198
F6.17
Power correction
coefficient
0.00
~
10.00
1.00
☆
199
F6.18
Multifunction key
definition 1
0 to 7
0
☆
200
F6.19
Multifunction key
definition 2
0 to 7
0
☆
201
F6.20 Keypad lock selection
0:RUN, STOP button valid
1:RUN, STOP, keypad encode valid
2: RUN, STOP, UP, DOWN button valid
3: STOP button valid
0
☆
202
F6.21
QUICK key function
selection
0: no function; 1: Jog running
2: Shift switch display state
3: FWD/RVS switchover
4: Clear-up UP/DOWN setting
5: Free stop
6: running command given in sequence
1
☆
5-1-9.F7 Auxiliary function group
No.
Code
Parameter name
Setting range
Factory
setting
Ch
an
ge
203
F7.00
Jog running
frequency
0.00Hz to F0.19(maximum frequency)
6.00Hz
☆
204
F7.01
Jog acceleration time 0.0s to 6500.0s
5.0s
☆
205
F7.02
Jog deceleration time 0.0s to 6500.0s
5.0s
☆
206
F7.03
Jog priority
0:Invalid 1: Valid
1
☆