Chapter 5 Function parameter
36
Ch
ap
ter 5
frequency point 3
147
F4.08
Multipoint V/F
voltage point 3
0.0% to 100.0%
0.0%
★
148
F4.09
Slip compensation
coefficient
0% to 200.0%
0.0%
☆
149
F4.10 Overexcitation gain
0 to 200
80
☆
150
F4.11
Oscillation
suppression gain
0 to 100
0
☆
151
F4.12
V/F separation
voltage source
0 to 9
0
☆
152
F4.13
V/F separation voltage
digital setting
0V to rated motor voltage
0V
☆
153
F4.14
V/F separation
voltage rise time
0.0s to 1000.0s
0.0s
☆
5-1-7.F5 Group - Vector control parameters
No. Code
Parameter name
Setting range
Factory
setting
Ch
ang
e
154
F5.00 Speed loop ratio G1
1 to 100
30
☆
155
F5.01 Speed loopintegral T1 0.01s to 10.00s
0.50s
☆
156
F5.02 Switching frequency 1 0.00 to F5.05
5.00Hz
☆
157
F5.03 Speed loop ratio G2
0 to 100
20
☆
158
F5.04
Speed loop integral
T2
0.01s to 10.00s
1.00s
☆
159
F5.05 Switching frequency 2 F5.02 to F0.19(max. frequency)
10.00Hz
☆
160
F5.06 Speed loop integral
0:valid 1:invalid
0
☆
161
F5.07
Torque limit upper
limit source
0 to 8
0
☆
162
F5.08
Upper limit digital
setting for torque
0.0% to 200.0%
150.0%
☆
163
F5.09
Vector control
differential gain
50% to 200%
150%
☆
164
F5.10
Speed loop filter time
constant
0.000s to 0.100s
0.000s
☆
165
F5.11
Vector control
overexcitation gain
0 to 200
64
☆
166
F5.12
Excitation regulator
proportional gain
0 to 60000
2000
☆
167
F5.13
Excitation regulator
integral gain
0 to 60000
1300
☆
168
F5.14
Torque regulator
proportional gain
0 to 60000
2000
☆
169
F5.15
Torque regulator
integral gain
0 to 60000
1300
☆