Chapter 5 Function parameter
50
Ch
ap
ter 5
3: Panel potentiometer setting
4: High-speed pulse setting
5: Communications reference
6: MIN (AI1, AI2)
7: MAX (AI1, AI2)
8.
High-speed pulse setting
300 FA.02
Torque figures setunder torque
control mode
-200.0% to 200.0%
150%
☆
301 FA.03 Torque control acceleration time
0.00s to 650.00s
0.00s
☆
302 FA.04 Torque control deceleration time
0.00s to 650.00s
0.00s
☆
303 FA.05
Torque control forward maximum
frequency
0.00Hz to F0.19(maximum
frequency)
50.00Hz
☆
304 FA.06
Torque control backward
maximum frequency
0.00Hz to F0.19 (maximum
frequency)
50.00Hz
☆
305 FA.07 Torque filter time
0.00s to 10.00s
0.00s
☆
5-1-13.FB Group - Control optimization parameters
No. Code
Parameter name
Setting range
Factory
setting
Chan-
ge
306 FB.00 Fast current limiting manner
0: Invalid 1: enable
1
☆
307 FB.01 Under-voltage point setting
50.0% to 140.0%
100.0%
☆
308 FB.02 Over-voltage point setting
200.0V to 2500.0V
810V
☆
309 FB.03
Deadband compensation mode
selection
0: no compensation
1: compensation mode 1
2: compensation mode 2
1
☆
310 FB.04 Current detection compensation 0 to 100
5
☆
311 FB.05
Vector optimization without PG
mode selection
0: no optimization
1: optimization mode 1
2: optimization mode 2
1
☆
312 FB.06
Upper limiting frequency for
DPWM switching
0.00Hz to 15.00Hz
12.00Hz
☆
313 FB.07 PWM modulation manner
0:asynchronous
;
1:synchronous
0
☆
314 FB.08 Random PWM depth
0: Invalid
1 to 10: PWM carrier frequency
random depth
0
☆
315 FB.09 Deadband time adjustment
100% to 200%
150%
☆
5-1-14.FC Group - Extended parameter group
No. Code
Parameter name
Setting range
Factory
setting
Chan-
ge
316 FC.00 Undefined
317 FC.01 Proportional linkage coefficient
0.00 to 10.00
0
☆
318 FC.02 PIDstart deviation
0.0 to 100.0
0
☆
5-1-15.E0 Group - Wobbulate, fixed-length and counting